background image

 4.1  Associating adaptive module to the Z-Wave network (LEARN MODE function)

Associating the adaptive module (controller) results in its being categorized as SECONDARY. Associating

the module with the network consists in sending data to it from PRIMARY controller. The procedure of associating the
module with the network is presented in Figure 3. In order to assure the best possible communication within the network
and after each its modification (including or removing a device): 

associating another controller with the network should be performed after associating all devices with the first
controller (“PRIMARY”),

or performing LEARN MODE again on the “SECONDARY” controller already associated with the network.

*) Programming error results from failure to receive any reply from the device which can be caused by: 

failure to enter LEARN MODE in the ZWMA module by pressing the “In/Ex” button three times until
the PRIMARY controller is signalling its readiness for adding a new device to the network: 

long distance between the controller and ZWMA module; 

the module is associated with another network and it is necessary to carry out the DEFAULT procedure
first.

13.11.21 NC825-GB

6/16

©2013, 

FAKRO

Figure 3: Associating ZWMA module with Z-Wave network 

3

.  Module  is  signaling  start  of 

associating  with  the  network  (two 
LEDs  on  as  presented  in  the 
drawing for app. 10 sec.). 

1

.Press “

In/Ex

” button once on the 

PRIMARY controller, e.g. 
ZWK15 keyboard. 

2

.  Press “

In/Ex

” button three times in 

ZWMA module which is to be added 
to the network.  

4

.  After  few  seconds,  the  module  is  signaling  that  associating  with  the 

network is complete (LEDs on as presented in the drawing for app. 2-3 sec.).

5*

.  Programming  error  –  two 

LEDs flashing  for app. 2-3 sec.

x3

Secondary

x1

Primary

Secondary

Primary

Primary

Secondary

Primary

Secondary

Note!!!

 

To control the devices form the controller “Secondary”, perform the ASSOCIATE function (see section 3.2) 

Note!!!

 

In the newer version of a controller, interrupting any procedure is possible by pressing the “IN/EX” button. In the older 

version, it is necessary to wait 10 seconds until the error is signalled by the controller or reset it by disconnecting the power 
supply.

Summary of Contents for ZWMA

Page 1: ...TE function 8 4 4 Return to default settings of the ZWMA adaptive module DEFAULT function 9 4 5 Removing the ZWMA adaptive module from the network 9 4 6 Additional functions 10 4 6 1 Configuring the Z...

Page 2: ...packing should be kept out of children s reach as thy may be a potential source of hazard The ZWMA module should be used for its intended purpose in agreement with its design The FAKRO Company shall n...

Page 3: ...m the digital input 1 channel 2 operated from the digital input 2 etc ZWMA adaptive module is equipped with a two way radio communication system Z Wave which uses radio frequency of 868 42 MHz Module...

Page 4: ...order to install the ZWMA module it is necessary to 1 Take off the cover terminal of the casing 2 Remount casing to the wall using screws 3 Make all the necessary electric conections 4 Screw the cover...

Page 5: ...that is first deleted from the pair of buttons section 3 4 and then removed from the network section 3 5 The correct implementation of the procedures is to ensure optimal communication between devices...

Page 6: ...o the network long distance between the controller and ZWMA module the module is associated with another network and it is necessary to carry out the DEFAULT procedure first 13 11 21 NC825 GB 6 16 201...

Page 7: ...device operates 13 11 21 NC825 GB 7 16 2013 FAKRO Figure 4 Device associating with selected input In ZWMA module 3 Module is signalling its readiness for associating the device with a selected channe...

Page 8: ...emory is not possible it is desirable to reconfigure the whole network all devices Start a new network configuration from restoring the controller to the factory settings DEFAULT function then call th...

Page 9: ...twork consists in restoring default settings in this module 13 11 21 NC825 GB 9 16 2013 FAKRO Figure 6 Restoring default settings in ZWMA controller Note In the newer version of a controller interrupt...

Page 10: ...the module has been earlier associated with the network as SECONDARY it is necessary to perform DEFAULT procedure 13 11 21 NC825 GB 10 16 2013 FAKRO Figure 7 Removing device from the Z Wave network u...

Page 11: ...another network or has not been assigned to any network It is necessary to perform EXCLUDE function on the device and then again perform INCLUDE and ASSOCIATE functions 13 11 21 NC825 GB 11 16 2013 FA...

Page 12: ...roper inputs here up and down arrows with appropriate COM input in ZWMA module as shown in Figure 9 Short circuit activates sending appropriate 13 11 21 NC825 GB 12 16 2013 FAKRO Figure 9 Adaptive mod...

Page 13: ...nalling of digital inputs LEDs Figure 1 no 5 for digital inputs inform about activation of connected controllers LED for input COM1 lights at short circuit of the contact responsible for sending comma...

Page 14: ...intended use as per user manual Damage is not a result of improperly made electrical system or atmospheric phenomena The manufacturer is not liable for damage which occurred as a result of improper u...

Page 15: ...13 11 21 NC825 GB 15 16 2013 FAKRO...

Page 16: ...FAKRO PP Sp z o o ul W gierska 144A 33 300 Nowy S cz Polska www fakro com tel 48 18 444 0 444 fax 48 18 444 0 333 13 11 21 NC825 GB 16 16 2013 FAKRO...