background image

 4  Module programming 

In order to operate electric FAKRO accessories equipped with the Z-WAVE system by means of

the ZWMA adaptive module, it is necessary to: 

1. Add the device to be operated by means of the module to the “Z-Wave” system – see ZWP10 remote

control and ZWK10, ZWK1 keyboards manuals, chapter “Adding device to the network (INCLUDE
function)” or other controller working in the Z-Wave system. If the device is already operated with one
of the controllers, proceed to section 2. 

2. Add the  module to the Z-Wave network as a SECONDARY controller, chapter 4.1 (LEARN MODE

function).

and

3. Associate the device with a selected channel in the module (No. 1, 

Figure

 

1

)  specifying the  task to be

performed by it (chapter 4.2, ASSOCIATE function).

Note!!! 

Any device which is physically removed from the network (e.g. damaged) should be deleted from the

memory of the controller (PRIMARY, SECONDARY), that is first deleted from the pair of buttons (section
3.4) and then removed from the network (section 3.5). The correct implementation of the procedures is to
ensure optimal communication between devices. Unplugging the device without removing it from the controller
memory will result in a prolonged reaction time to commands and faster depletion of the controller battery. If it
is necessary to remove the damaged equipment, whose removal from the controller memory is not possible, it is
desirable to reconfigure the whole network (all devices). Start a new network configuration from restoring the
controller to the factory settings (DEFAULT function), then call the EXCLUDE function of devices working
correctly and continue to the section  3, "Controller Programming".

 

Note!!!  

Moving the device within the network (e.g. socket module) it is recommended to delete it from the

controller memory (delete it from the pair of buttons first (section 3.4) and then remove from the network
(section 3.5) and then add it again after installation in new place of work.

13.11.21 NC825-GB

5/16

©2013, 

FAKRO

Summary of Contents for ZWMA

Page 1: ...TE function 8 4 4 Return to default settings of the ZWMA adaptive module DEFAULT function 9 4 5 Removing the ZWMA adaptive module from the network 9 4 6 Additional functions 10 4 6 1 Configuring the Z...

Page 2: ...packing should be kept out of children s reach as thy may be a potential source of hazard The ZWMA module should be used for its intended purpose in agreement with its design The FAKRO Company shall n...

Page 3: ...m the digital input 1 channel 2 operated from the digital input 2 etc ZWMA adaptive module is equipped with a two way radio communication system Z Wave which uses radio frequency of 868 42 MHz Module...

Page 4: ...order to install the ZWMA module it is necessary to 1 Take off the cover terminal of the casing 2 Remount casing to the wall using screws 3 Make all the necessary electric conections 4 Screw the cover...

Page 5: ...that is first deleted from the pair of buttons section 3 4 and then removed from the network section 3 5 The correct implementation of the procedures is to ensure optimal communication between devices...

Page 6: ...o the network long distance between the controller and ZWMA module the module is associated with another network and it is necessary to carry out the DEFAULT procedure first 13 11 21 NC825 GB 6 16 201...

Page 7: ...device operates 13 11 21 NC825 GB 7 16 2013 FAKRO Figure 4 Device associating with selected input In ZWMA module 3 Module is signalling its readiness for associating the device with a selected channe...

Page 8: ...emory is not possible it is desirable to reconfigure the whole network all devices Start a new network configuration from restoring the controller to the factory settings DEFAULT function then call th...

Page 9: ...twork consists in restoring default settings in this module 13 11 21 NC825 GB 9 16 2013 FAKRO Figure 6 Restoring default settings in ZWMA controller Note In the newer version of a controller interrupt...

Page 10: ...the module has been earlier associated with the network as SECONDARY it is necessary to perform DEFAULT procedure 13 11 21 NC825 GB 10 16 2013 FAKRO Figure 7 Removing device from the Z Wave network u...

Page 11: ...another network or has not been assigned to any network It is necessary to perform EXCLUDE function on the device and then again perform INCLUDE and ASSOCIATE functions 13 11 21 NC825 GB 11 16 2013 FA...

Page 12: ...roper inputs here up and down arrows with appropriate COM input in ZWMA module as shown in Figure 9 Short circuit activates sending appropriate 13 11 21 NC825 GB 12 16 2013 FAKRO Figure 9 Adaptive mod...

Page 13: ...nalling of digital inputs LEDs Figure 1 no 5 for digital inputs inform about activation of connected controllers LED for input COM1 lights at short circuit of the contact responsible for sending comma...

Page 14: ...intended use as per user manual Damage is not a result of improperly made electrical system or atmospheric phenomena The manufacturer is not liable for damage which occurred as a result of improper u...

Page 15: ...13 11 21 NC825 GB 15 16 2013 FAKRO...

Page 16: ...FAKRO PP Sp z o o ul W gierska 144A 33 300 Nowy S cz Polska www fakro com tel 48 18 444 0 444 fax 48 18 444 0 333 13 11 21 NC825 GB 16 16 2013 FAKRO...