background image

 4.6  Additional functions

 4.6.1  Configuring the Z-Wave network using the ZWMA adaptive module (INCLUDE function).

Adding a device to the “Z-Wave” network is possibly only with the use of PRIMARY controller

(e.g. keyboard ZWK10, ZWK1, ZWP10, ZWPTV). The ZWMA module should be associated with the network
as SECONDARY. However, there is a possibility of programming the module for the network as PRIMARY.
The procedure of device adding to the network with the use of the ZWMA module is presented in Figure 7.  

*) Programming error results from the fact of not receiving any response from the device and may be caused
by:

failure to press the programming button within 10 seconds  from the module signalling its readiness for
adding the device to the network; 

long distance between the module and the device being added;

the module has been earlier associated with the network as “SECONDARY” – it is necessary to perform
DEFAULT procedure.

13.11.21 NC825-GB

10/16

©2013, 

FAKRO

Figure 7: Removing device from the Z-Wave network using ZWMA adaptive module 

4

. The controller is signaling that 

the device has been successfully 
associated with the network (two  
LEDs on for app. 2-3 sec.). For 
operating accessories with the use 
of the module, proceed to section 
4.2.

5*

. Programming error – two 

external LEDs flashing for app. 
2-3 sec.

2

.  The controller is signaling 

its readiness for adding a new 
device to the network (two 
external LEDs on for 10 sec.).  

3

.  Press “P” button on the device and 

hold it more than 0.5 sec.  (see Device 
Programming Manual).  

1

.  Press “

In/Ex

” button once.

x1

x1
>0,5Sec.

Note!!!

 

In the newer version of a controller, interrupting any procedure is possible by pressing the “IN/EX” button. In the older 

version, it is necessary to wait 10 seconds until the error is signalled by the controller or reset it by disconnecting the power 
supply.

Summary of Contents for ZWMA

Page 1: ...TE function 8 4 4 Return to default settings of the ZWMA adaptive module DEFAULT function 9 4 5 Removing the ZWMA adaptive module from the network 9 4 6 Additional functions 10 4 6 1 Configuring the Z...

Page 2: ...packing should be kept out of children s reach as thy may be a potential source of hazard The ZWMA module should be used for its intended purpose in agreement with its design The FAKRO Company shall n...

Page 3: ...m the digital input 1 channel 2 operated from the digital input 2 etc ZWMA adaptive module is equipped with a two way radio communication system Z Wave which uses radio frequency of 868 42 MHz Module...

Page 4: ...order to install the ZWMA module it is necessary to 1 Take off the cover terminal of the casing 2 Remount casing to the wall using screws 3 Make all the necessary electric conections 4 Screw the cover...

Page 5: ...that is first deleted from the pair of buttons section 3 4 and then removed from the network section 3 5 The correct implementation of the procedures is to ensure optimal communication between devices...

Page 6: ...o the network long distance between the controller and ZWMA module the module is associated with another network and it is necessary to carry out the DEFAULT procedure first 13 11 21 NC825 GB 6 16 201...

Page 7: ...device operates 13 11 21 NC825 GB 7 16 2013 FAKRO Figure 4 Device associating with selected input In ZWMA module 3 Module is signalling its readiness for associating the device with a selected channe...

Page 8: ...emory is not possible it is desirable to reconfigure the whole network all devices Start a new network configuration from restoring the controller to the factory settings DEFAULT function then call th...

Page 9: ...twork consists in restoring default settings in this module 13 11 21 NC825 GB 9 16 2013 FAKRO Figure 6 Restoring default settings in ZWMA controller Note In the newer version of a controller interrupt...

Page 10: ...the module has been earlier associated with the network as SECONDARY it is necessary to perform DEFAULT procedure 13 11 21 NC825 GB 10 16 2013 FAKRO Figure 7 Removing device from the Z Wave network u...

Page 11: ...another network or has not been assigned to any network It is necessary to perform EXCLUDE function on the device and then again perform INCLUDE and ASSOCIATE functions 13 11 21 NC825 GB 11 16 2013 FA...

Page 12: ...roper inputs here up and down arrows with appropriate COM input in ZWMA module as shown in Figure 9 Short circuit activates sending appropriate 13 11 21 NC825 GB 12 16 2013 FAKRO Figure 9 Adaptive mod...

Page 13: ...nalling of digital inputs LEDs Figure 1 no 5 for digital inputs inform about activation of connected controllers LED for input COM1 lights at short circuit of the contact responsible for sending comma...

Page 14: ...intended use as per user manual Damage is not a result of improperly made electrical system or atmospheric phenomena The manufacturer is not liable for damage which occurred as a result of improper u...

Page 15: ...13 11 21 NC825 GB 15 16 2013 FAKRO...