 1  Safety rules

Read the instructions below carefully before proceeding to device installation so as to
avoid electric shock, injury etc. 

CAUTION!!!

The ZWMA  module is powered by 230V alternating current. Electric shock hazard.  

When   installing   the   ZWMA   module   it   is   crucial   to   pay   close   attention   to   the   following
recommendations: 

Installation   should   be   performed   by   a   qualified   individual   following   manufacturer's
instructions.

Connecting the module should be performed with power supply disconnected at all times.  

After unpacking, check module elements for any signs of mechanical damage.  

Before connecting the module, make sure that the power supply voltage corresponds with
that provided on the data plate.  

Plastic containers used for packing should be kept out of children's reach as thy may be a
potential source of hazard.  

The ZWMA module should be used for its intended purpose in agreement with its design.
The FAKRO Company shall not be held responsible for any consequences resulting from
improper module use.  

Any activities relating to cleaning, adjustment or disassembly of the module   should be
preceded with its disconnection from the mains.  

The module should not be cleaned using any solvent substances or open stream of water
(do not immerse in water). 

Any module repairs should be carried out by the manufacturer authorised service.  

Electric   cables   supplying   electricity   to   the   source   of   power   must   have   suitable   area
(2x1mm

2

). The permissible cable length for the area specified above is 30 rm.  

The permissible length of cables plugged into digital inputs is 5 rm.  

The ZWMA adaptive module is intended for indoor installation.  

13.11.21 NC825-GB

2/16

©2013, 

FAKRO

Summary of Contents for ZWMA

Page 1: ...TE function 8 4 4 Return to default settings of the ZWMA adaptive module DEFAULT function 9 4 5 Removing the ZWMA adaptive module from the network 9 4 6 Additional functions 10 4 6 1 Configuring the Z...

Page 2: ...packing should be kept out of children s reach as thy may be a potential source of hazard The ZWMA module should be used for its intended purpose in agreement with its design The FAKRO Company shall n...

Page 3: ...m the digital input 1 channel 2 operated from the digital input 2 etc ZWMA adaptive module is equipped with a two way radio communication system Z Wave which uses radio frequency of 868 42 MHz Module...

Page 4: ...order to install the ZWMA module it is necessary to 1 Take off the cover terminal of the casing 2 Remount casing to the wall using screws 3 Make all the necessary electric conections 4 Screw the cover...

Page 5: ...that is first deleted from the pair of buttons section 3 4 and then removed from the network section 3 5 The correct implementation of the procedures is to ensure optimal communication between devices...

Page 6: ...o the network long distance between the controller and ZWMA module the module is associated with another network and it is necessary to carry out the DEFAULT procedure first 13 11 21 NC825 GB 6 16 201...

Page 7: ...device operates 13 11 21 NC825 GB 7 16 2013 FAKRO Figure 4 Device associating with selected input In ZWMA module 3 Module is signalling its readiness for associating the device with a selected channe...

Page 8: ...emory is not possible it is desirable to reconfigure the whole network all devices Start a new network configuration from restoring the controller to the factory settings DEFAULT function then call th...

Page 9: ...twork consists in restoring default settings in this module 13 11 21 NC825 GB 9 16 2013 FAKRO Figure 6 Restoring default settings in ZWMA controller Note In the newer version of a controller interrupt...

Page 10: ...the module has been earlier associated with the network as SECONDARY it is necessary to perform DEFAULT procedure 13 11 21 NC825 GB 10 16 2013 FAKRO Figure 7 Removing device from the Z Wave network u...

Page 11: ...another network or has not been assigned to any network It is necessary to perform EXCLUDE function on the device and then again perform INCLUDE and ASSOCIATE functions 13 11 21 NC825 GB 11 16 2013 FA...

Page 12: ...roper inputs here up and down arrows with appropriate COM input in ZWMA module as shown in Figure 9 Short circuit activates sending appropriate 13 11 21 NC825 GB 12 16 2013 FAKRO Figure 9 Adaptive mod...

Page 13: ...nalling of digital inputs LEDs Figure 1 no 5 for digital inputs inform about activation of connected controllers LED for input COM1 lights at short circuit of the contact responsible for sending comma...

Page 14: ...intended use as per user manual Damage is not a result of improperly made electrical system or atmospheric phenomena The manufacturer is not liable for damage which occurred as a result of improper u...

Page 15: ...13 11 21 NC825 GB 15 16 2013 FAKRO...

Page 16: ...FAKRO PP Sp z o o ul W gierska 144A 33 300 Nowy S cz Polska www fakro com tel 48 18 444 0 444 fax 48 18 444 0 333 13 11 21 NC825 GB 16 16 2013 FAKRO...

Reviews: