![Fairford Electronics QFE Series Manual Download Page 87](http://html1.mh-extra.com/html/fairford-electronics/qfe-series/qfe-series_manual_3218507087.webp)
FD8416 5MC Bit Parameters
03 September 2003
55
55
55
55
Software
.
11
11
11
11
USER FLAGS 3
53
Bitmask
Name
Type
Default
= ON
Description
Parameter
pf1 pol
read/write
Polarity of programmable flags (1)
00000001
(
)
1
pf2 pol
read/write
Polarity of programmable flags (2)
00000010
(
)
2
User Current limit
read/write
Bus requests a Start ramp hold
00000100
(
)
4
User trip
read/write
Bus requests a trip
00001000
(
)
8
Invert Controller
input
read/write
Controller set point source is
inverted before use in servo loop
00010000
(
)
16
Inhibit Restart
read/write
Inhibited restart control is enabled
00100000
(
)
32
Unused
Status
01000000
(
)
64
I/O POLARITY
54
Bitmask
Name
Type
Default
= ON
Description
Parameter
K1 Polarity
read/only
00000001
(
)
1
K2 Polarity
read/only
00000010
(
)
2
K3 Polarity
read/only
00000100
(
)
4
K4 Polarity
read/only
00001000
(
)
8
I/P 1 Polarity
read/only
00010000
(
)
16
I/P 2 Polarity
read/only
00100000
(
)
32
I/P 3 Polarity
read/only
01000000
(
)
64
LED Polarity
(unused)
read/only
10000000
(
)
128
Page 4 of 8
Summary of Contents for QFE Series
Page 18: ...Mechanical Installation QFE page 1 2 FD841205_F...
Page 26: ...Mechanical Installation QFE page 1 10 FD841205_F...
Page 43: ...QFE page 2 19 Electrical Installation FD8413 issue03_F...
Page 50: ...Electrical Installation QFE page 2 26 FD8413 issue03_F...
Page 51: ...QFE Soft Start Motor Controller Technical Data for the QFE and QFEplus Applications...
Page 73: ...QFE page 3 25 Applications FD841405_F...
Page 158: ...page 5 47 Programming QFE FD8420 issue02_F This page is left intentionally blank...
Page 181: ...Modbus page 6 4 5MC FD510007...