The stove switches off.
Alarm
8
displayed:
“FAILURE DEPRESS”
The door isn’t closed
The waste outlet is obstructed
The rubber pipe of the pressure switch
is obstructed
Pressure switch is faulty
Electronic card is faulty
Excessive chimney length
Bad weather conditions
Closed the door properly and check
the door strips are in good conditions
otherwise replace them.
The fumes waste chimney is
partially or totally obstructed (call an
expert stove fitter to check the
chimney from the stove outlet to the
chimney pot). Have it cleaned
immediately.
Take the pressure switch silicone
pipe off and with the help of a
pointed tool clean the bodying hole.
Replace the pipe if necessary.
Replace the pressure switch. Call a
specialised technician.
Replace the card. Call a specialised
technician
Call an expert stove setter to verify if
the chimney is according to the law
(see paragraph 2).
When there is a very strong wind a
negative depression to the chimney
can occur. Verify and start the stove
again.
The stove switches OFF.
Alarm
7
displayed
“SAFETY THERMAL”
Stove overheated
Temporary power failure
Faulty thermostat
Air vent obstructed
Faulty electronic card
Faulty temperature probe
The water temperature has exceeded
the maximum set value
The set power is excessive compared
to the hydraulic system
Let the stove cool down and stoke it
again, if the problem continues, call
a specialised technician.
A voltage failure during the
functioning of the stove causes an
overheating of the boiler and it is
necessary to stoke it again and start
the stove.
Replace the thermostat. Call a
specialised technician.
Clean the air vent
Replace the temperature probe. Call
a specialised technician.
Replace the card.. Call a specialised
technician.
Let the stove cool down and proceed
with re-ignition. If the problem
persists, contact a specialized
technician.
Lower the stove power
The stove switches off.
Alarm 2 is displayed
“PROBE EXHAUST”
Fumes feeler is faulty
Electronic card faulty
Replace
the
feeler.
Call
a
specialised technician.
Replace the card. Call a specialised
technician.
The stove switches off.
Alarm 3 displayed “HOT
EXAUST”
Fumes
temperature
feeler
disconnected
Fumes temperature feeler is faulty
The stove is in overheating
Verify the feeler is connected to the
card and/or put in and blocked in the
seat of the extractor. Call a
specialised technician.
Replace
the
feeler.
Call
a
specialised technician.
Let the stove cool down and restart
it, contact a specialized technician.
The stove switches off.
"PRESS WATER" display
alarm E.
The water pressure inside the stove is
too high
Drain some water using the special
tap and check that the pressure is
below 2 bar. Make sure the system
is completely vented from the air.