background image

The  stove  switches  off. 
Alarm 

displayed: 

“FAILURE DEPRESS” 

 

The door isn’t closed 

 

The waste outlet is obstructed 

 

The rubber pipe of the pressure switch 
is obstructed 

 

Pressure switch is faulty 

 

Electronic card is faulty 

 

Excessive chimney length 

 

Bad weather conditions 

 

Closed the door properly and check 
the door strips are in good conditions 
otherwise replace them. 

 

The  fumes  waste  chimney  is 
partially or totally obstructed (call an 
expert  stove  fitter  to  check  the 
chimney from the stove outlet to the 
chimney  pot).  Have  it  cleaned 
immediately. 

 

Take  the  pressure  switch  silicone 
pipe  off  and  with  the  help  of  a 
pointed tool clean the bodying hole. 
Replace the pipe if necessary. 

 

Replace the pressure switch. Call a 
specialised technician. 

 

Replace the card. Call a specialised 
technician 

 

Call an expert stove setter to verify if 
the chimney is according to the law 
(see paragraph 2). 

 

When there is a very strong wind a 
negative depression to the chimney 
can occur. Verify and start the stove 
again. 

The stove switches OFF. 
Alarm 

displayed 

“SAFETY THERMAL” 

 

Stove overheated  

 

Temporary power failure 

 

Faulty thermostat 

 

Air vent obstructed 

 

Faulty electronic card 

 

Faulty temperature probe 

 

The  water  temperature  has  exceeded 
the maximum set value 

 

The set power is excessive compared 
to the hydraulic system 

 

Let the stove cool down and stoke it 
again, if the problem continues, call 
a specialised technician. 

 

A  voltage  failure  during  the 
functioning  of  the  stove  causes  an 
overheating  of  the  boiler  and  it  is 
necessary to stoke it again and start 
the stove. 

 

Replace  the  thermostat.  Call  a 
specialised technician. 

 

Clean the air vent 

 

Replace the temperature probe. Call 
a specialised technician. 

 

Replace the card.. Call a specialised 
technician. 

 

Let the stove cool down and proceed 
with  re-ignition.  If  the  problem 
persists,  contact  a  specialized 
technician. 

 

Lower the stove power 

The  stove  switches  off. 
Alarm  2  is  displayed 
“PROBE EXHAUST” 

 

Fumes feeler is faulty 

 

Electronic card faulty 

 

 

Replace 

the 

feeler. 

Call 

specialised technician. 

 

Replace the card. Call a specialised 
technician. 

 

The  stove  switches  off. 
Alarm  3  displayed  “HOT 
EXAUST” 

 

Fumes 

temperature 

feeler 

disconnected 

 

Fumes temperature feeler is faulty 

 

The stove is in overheating 

 

Verify the feeler is connected to the 
card and/or put in and blocked in the 
seat  of  the  extractor.  Call  a 
specialised technician. 

 

Replace 

the 

feeler. 

Call 

specialised technician. 

 

Let the stove cool down and restart 
it, contact a specialized technician. 

The stove switches off. 
"PRESS WATER" display 
alarm E.  

 

The water pressure inside the stove is 
too high 

 

Drain some water using the special 
tap  and  check  that  the  pressure  is 
below 2 bar. Make sure the system 
is completely vented from the air. 

 

Summary of Contents for H18

Page 1: ......

Page 2: ...way be used without the hydraulic connection and without water being loaded in the heat chamber This stove should be used for the purposes for which it was designed and made The manufacturer is exclu...

Page 3: ...with the regulation in force UNI10683 Chimney flue The chimney flue or chimney has a great importance for a heating appliance which uses solid combustible materials of b type with forced draft as mode...

Page 4: ...imney flue draught depends also on its height The draught which is necessary for the different models of pellets stoves is 8pa to 14pa 0 08 to 0 14mbar Dimensions The section can be round which is the...

Page 5: ...pot must be cleaned and checked by an expert at least once a year Safety can be compromised by the non cleaning Pic 4 External air intake We recommend to set an air intake from the outside to have a h...

Page 6: ...ling a permanent ventilation grid in a window or near the stove Air intake directly from the outside is compulsory WARNING Use only certified pipes of steel preferably Pipes in synthetic material must...

Page 7: ...ickness 0 5mm with a diameter of 80 mm or 100mm depending on the type of plant see picture 2 pag 4 you can not use pipes made of asbestos cement or flexible metal The pipes must be sealed with high te...

Page 8: ...characteristics and quality on sale We recommend to use pellets of good quality as that has great influence on the heating capacity and on the residuals of ash Pellets characteristics are diameter of...

Page 9: ...h fire prevention methods there must be a minimum distance of at least 20 cm from flammable objects to the back and side of the stove and of 80 cm to the front where the fire door is If the floor is m...

Page 10: ...y check that the system pressure is always kept between 0 5 and 1 5 bar IMPORTANT If for any reason the pressure should increase or decrease it is advised to troubleshoot and reset the pressure PRESSU...

Page 11: ...olated heat exchanger 25 35 kW or an accumulator puffer based on the system type The hydraulic system is equipped with a 6 lt closed surge tank with a precharge pressure of 1 bar To display the heat c...

Page 12: ...vice Children should not be present because the vapours emitted by the stove may be harmful to health Adults should also avoid staying for long near the stove Do not touch the surfaces as they may sti...

Page 13: ...em water pressure is displayed in Bar Key 6 pressed once allows to set the power of the stove Keys 5 and 6 in the programming mode the menus are scrolled Display shows the board status during start up...

Page 14: ...ver 3 5 years Press button 3 scroll with buttons 5 or 6 until the display views menu 01 Access by pressing button 3 once again Use buttons 1 or 2 to select the current day of the week Press button 3 t...

Page 15: ...her press button 4 three times M 2 2 program day This entry enables disables and sets all the daily clock thermostat functions You can use 2 separate programs to start and stop the stove Use buttons 1...

Page 16: ...t which you would like the stove to turn on automatically or else set value at OFF to disable start up of program 1 Press button 3 to continue setting Use buttons 1 or 2 to select the time at which yo...

Page 17: ...ON ON ON OFF OFF Progr 2 h 11 00 h 13 00 ON ON ON ON ON OFF OFF Progr 3 h 17 00 h 21 00 ON ON ON ON ON OFF OFF Progr 4 h 10 00 h 20 00 OFF OFF OFF OFF OFF ON ON To return to the level of the previous...

Page 18: ...gue language from among those available ITALIANO ENGLISH DEUTSCH FRANCAIS ESPANOL PORTUGUES Press button 3 and scroll with buttons 1 or 2 until the display views menu 04 Access by pressing button 3 on...

Page 19: ...hlea To stop loading press button 4 To return to the level of the previous menu and to continue scrolling among the various entries of the menu press button 4 once To exit the menu altogether press bu...

Page 20: ...e thermostat falls below the set threshold the stove will restart and return to work or will switch back on if the stand by is active With this mode the stove does not take into account in any way the...

Page 21: ...he value will be confirmed automatically Modulating function energy saving When the room temperature or the water temperature reaches the temperature set on the stove its power automatically goes to m...

Page 22: ...ue use a carbon dioxide CO2 fire extinguisher or ask for the fire brigade intervention Do not use water to put out the fire in the brazier Pellets stoking If you have to stoke the stove with pellets w...

Page 23: ...es to cool the stove down Let the stove cool down and then switch it off with the 4 ON OFF key Verify the occurring fault on page 31 After detecting the cause of the fault clean up the brazier and res...

Page 24: ...arm described above is triggered Let the stove cool down and then switch it off with the 4 ON OFF key To reset the thermostat unscrew the black cap behind the stove and press the pin that comes out of...

Page 25: ...e to remind you that the majolica parts are craft made and therefore they can have little flaws flaws interlacing due to thermal dilation between the biscuit and the paint marking by tricks very littl...

Page 26: ...eaning You must empty the ash draw when full The ash should be put in a metal container with airtight lid and it shouldn t get in contact with combustible material ex left on a wooden floor as the ash...

Page 27: ...mbar Emissions CO at 13 of O2 0 016 0 025 0 016 0 025 0 016 0 025 Emissions CO2 7 16 10 74 7 16 10 74 7 16 10 74 Average temperature fumes 60 136 C 80 145 C 80 145 C Mass flow fumes 7 8 15 3 g s 7 8...

Page 28: ...dimensions H25 HC25 A Control panel B Water drain in overpressure Female heating 1 2 C Combustion air inlet ex 42 mm D Heating DELIVERY Male l E Heating RETURN Male l F Fumes drain pipe 80 mm G Water...

Page 29: ...ctor Pump ALF General safety thermostat ALC Pressure Glow plug Cochlea encoder fumes extractor Fumes feeler Thermostat additional NTC 300 C feeler Ambience feeler Flowmeter not present ACCESSORIES not...

Page 30: ...you shall open the T fitting vacuum the dust from the surface having then the foresight to close it properly 4 Clean and empty the ash pan before it is completely filled 5 Check that the pellet hoppe...

Page 31: ...lets must be stored in a dry room Verify Replace the feeler Call a specialised technician Replace the card Call a specialised technician Restart the stove and check if the problem persists Pellets don...

Page 32: ...old Temperature fumes feeler is faulty Electronic card is faulty Replace the fumes feeler Call a specialised technician Replace the card Call a specialised technician Ashes around the stove Faulty or...

Page 33: ...excessive compared to the hydraulic system Let the stove cool down and stoke it again if the problem continues call a specialised technician A voltage failure during the functioning of the stove cause...

Page 34: ...entioned Guarantee period For example the glow plug gaskets the brazier the firebox lining ceramic glass painted parts of ceramic etc The guarantee is valid for 24 months from the date of first startu...

Page 35: ...e apparatus to you or to our nearest Technical Servicing Centre specifying the model and serial number and describing the problem Also bear in mind that original spare parts can be obtained only and e...

Page 36: ...r s signature Segnature of TSC Specialised Technical Servicing Centre Work done on Material used Guarantee YES NO YES NO YES NO YES NO User s signature Segnature of TSC Specialised Technical Servicing...

Page 37: ...r s signature Segnature of TSC Specialised Technical Servicing Centre Work done on Material used Guarantee YES NO YES NO YES NO YES NO User s signature Segnature of TSC Specialised Technical Servicing...

Page 38: ...NOTES...

Page 39: ......

Page 40: ...Technical Office Fair 2018 Rev 5 01 03 2018 EN FAIR srl Via Lago di Costanza 24 Z I 36015 Schio Vicenza Italia Tel 39 0445 698000 Fax 39 0445 698100 www fair europe com info fair europe com...

Reviews: