background image

PERFORMANCE OF THE BARRIER IN RELATION TO OPENING TIMES

TECHNICAL SPECIFICATIONS - BAYT 980 -

180

ø 66

ø 16

Elettric motor

ø 140 - 0.5 HP - 0.37 KW

Condenser......20 

μ

F

140

370

790

148

250

230

345

STROKE

ø 16

COS 982 DRIVE UNIT DIMENSION MEASUREMNTS

FIG. 33

230

Cos 982

Hydraulic drive unit

              

Series   ........P6

                    "      .........P12

                    "      .........P20

Do not put oil into the reservoir. 

It has already been filled. 

Bayt 980

Oil-hydraulic

!

page 

19

Made in Italy

the gate opener

Bayt 980

TECHNICAL SPECIFICATIONS

ELECTRIC MOTORS

Power output 

  0,37 kW (0,5 HP)

Absorbed power 

  510  W

Frequency 

  50  Hz

Supply voltage 

  230  Vac

Absorbed current 

  2,4  A

Capacitor 

  20  µF

Motor rotation speed 

  1.350  rpm

Intermittent service 

  S3

OIL-HYDRAULIC MOTOR-PUMP UNIT - COS 982 -

Working pressure 

  20  atm

Max. pressure 

  40  atm

Oil type 

  Oil Fadini - Item 708L

Reservoire capacity 

  2,5  liters

Static weight 

  22,5  kg

Working temperature 

  -20 °C +80 °C (*)

Protection standards 

  IP 65 (inside the housing)

Weight (without beam) 

 75  kg

Colour of the housing 

 RAL 2002 Orange Red

Door and top colour 

  Metallic grey, pebbled

(*) -40 °C with specific optional accessories (Ref. General Catalogue).

PERFORMANCE 

(4 s - 4,20 m beam)

Frequency of use 

very intensive

Service cycle 

   opening 4 s - dwell 4 s - closing 4 s - dwell 4 s

Complete cycle time 

16 s

Complete cycles opening-dwell-closing-dwell 

No. 225/hour

Annual cycles (with 8 hours of use per day) 

No. 657.000

PERFORMANCE

 (14 s - 6,40 m beam with fence)

Frequency of use 

very intensive

Service cycle 

opening 14 s - dwell 7 s - closing 14 s - dwell 7 s

Complete cycle time 

42 s

Complete cycles opening-dwell-closing-dwell 

No. 86/hour

Annual cycles (with 8 hours of use per day) 

No. 251.000

PERFORMANCE 

(8 s - 6,40 m beam)

Frequency of use 

very intensive

Service cycle  

opening 8 s - dwell 4 s - closing 8 s - dwell 4 s

Complete cycle time 

24 s

Complete cycles opening-dwell-closing-dwell 

No. 150/hour

Annual cycles (with 8 hours of use per day) 

No. 438.000

PERFORMANCE 

(19 s - 8,50 m beam with fence)

Frequency of use 

very intensive

Service cycle 

opening 19 s - dwell 10 s - closing 19 s - dwell 10 s

Complete cycle time 

58 s

Complete cycles opening-dwell-closing-dwell 

No. 62/hour

Annual cycles (with 8 hours of use per day) 

No. 181.000

Summary of Contents for BAYT 980

Page 1: ...8 metres wide Version with aluminium fencing Version with cabled hinged road barrier beam Folding or fixed leg with yoked pedestal Fully convertible to right and left versions BAYT 980 Oleodinamica Fi...

Page 2: ...of the accessories there are no sources of electromagnetic disturbances such that the magnetic electromagnetic fields of any possible metallic mass detection loops and of all the system command and c...

Page 3: ...stal with yoke 5 Base foundation in concrete 500x500x600 mm 6 50mm conduit for service cabling 7 Level both sides 8 Four M14 anchor bolts that extend for 65 mm Internal side of the closure of the driv...

Page 4: ...ormed after having set the Bayt 980 foundation plate at a distance determined by the length of the barrier beam from the fixed pedestal 2 80 mm out of line from the corner of the housing cabinet base...

Page 5: ...s in the output of their respective electronic programmer terminals Bayt 980 LH Left FIG 7 HOW TO MAKE THE LEFT HANDED BAYT INTO A RIGHT HANDED BAYT AND VICE VERSA BAY T 980 BAY T 980 Bayt 980 RH Righ...

Page 6: ...UPSIDE DOWN 4 FIG 10 R532 R532 R532 FIG 11 Barrier beam 3 20 2 10 2 10 4 20 3 20 2 10 5 30 3 20 3 20 6 40 3 20 2 10 2 10 7 40 3 20 3 20 2 10 8 50 metres 2 85 3 85 4 95 6 05 7 05 8 15 Actual length ma...

Page 7: ...ith aluminium fencing length metres 3 80 length metres 4 75 length metres 5 89 length metres 6 84 length metres 7 98 R532 Coupling strut FIG 13 INSTALLATION OF COUNTERWEIGHTS ON THE BAYT 980 F D E D 2...

Page 8: ...ay closure C to be covered The length C is given by the sum of A B Ceiling height H Barrier beam length A Metal cable length L Opening time 2 50 m 2 70 m 2 80 m 3 00 m 3 70 m 4 10 m 1 60 m 1 80 m 1 90...

Page 9: ...In order to install the Polo 44 photocells and the Prit 19 selector switch on the housing cabinet it is necessary to remove the protective covers 22 unscrewing the M8 nut 20 from inside of the cabine...

Page 10: ...CT 7 3 Open Close normal Reserve direction on each impulse Step by step 2 DIP SWITCH 2 ON Does not reverse on opening OFF Reverses direction on every impulse 5 DIP SWITCH 5 ON Step by Step with interm...

Page 11: ...n Italy 1224 26 08 M Traffic signal PCB TIME PAUSE F1 F2 F3 16 17 18 19 20 21 22 1 2 3 4 5 6 7 8 9 10 11 12 ON 24 Vdc 150mA _ NEUTRAL PHASE COMMON 18 20 19 16 17 21 22 M 1 2 3 4 5 6 7 8 9 10 11 12 13...

Page 12: ...e 13 24mm spanner Important ADJUSTMENT OF THE BARRIER BEAM IN CLOSING POSITION Fig 23 In closing the barrier beam must be horizontal therefore the adjustment is performed with the piston rod completel...

Page 13: ...NOT Vertical NOT Horizontal Half stroke Important FIG 25 Adjustment flange RING NUT C3 anti clockwise direction Rh Loosen The barrier beam goes beyond the perpendicular and stops The barrier beam sto...

Page 14: ...ng rod 3rd Lower attachment pin yoke reservoir piston Cos 982 GREASE every three months FIG 27 Periodically it is necessary to perform maintenance to the Bayt 980 barrier injecting grease by way of su...

Page 15: ...servoir of the Cos 982 the piston must be perpendicular to the housing cabinet of the Bayt 980 In the Cos 982 hydraulic piston it is possible to adjust the thrust force necessary for the movement of t...

Page 16: ...e installer must apply all safety regulations to it The same installer must also issue his her own Declaration of Conformity The manufacturing firm assumes no responsibility for the improper use of th...

Page 17: ...mechanism according to the provisions of the law is a machine and therefore the installer must apply all safety regulations to it The same installer must also issue his her own Declaration of Conformi...

Page 18: ...Red Colour of painted cover and door Textured metalized 55 100 3 200 700 170 850 20 1752 840 990 150 150 70 86 175 200 Aluminium fencing to be attached to the bottom of the barrier beam Modules of 0...

Page 19: ...Red Door and top colour Metallic grey pebbled 40 C with specific optional accessories Ref General Catalogue PERFORMANCE 4 s 4 20 m beam Frequency of use very intensive Service cycle opening 4 s dwell...

Page 20: ...o Counterweights no Spring Barrier beam 3 20 m no Fence no Cables no Counterweights piston 40 with Spring Barrier beam 4 20 m Barrier beam 5 30 m Barrier beam 6 40 m with Spring with Spring Barrier be...

Reviews: