3. S800 ENC

3.1  

INTENDED USE

Underground actuators of the FAAC S800 ENC series are designed 
to activate horizontally moving swing gates for residential/condo-
minium use.
One underground actuator must be installed for each leaf.
The systems set up with S800 ENC must only be intended for vehicle 
transit.
See the instructions in § 8.3 to move the gate by hand.

 

!

Any other use, not specifically described, is prohibited and might affect 
the integrity of the product and/or be a source of danger.

3.2  LIMITS OF USE

 

-

Do not use the automation when its range of action is not clear 
of people, animals or objects.

 

-

Do not pass and/or stop within the automation's range of action 
while it is moving.

 

-

Do not obstruct the movement of the automation.

 

-

Do not climb onto, hold onto or be pulled by the leaf.

 

-

Do not allow children to come close or play near the automation's 
range of action.

 

-

Do not allow the control devices to be used by persons who are 
not specifically authorised and trained.

 

-

Do not allow the control devices to be used by children or persons 
with reduced mental-physical abilities, unless under the supervi-
sion of an adult responsible for their safety.

 

!

When moving it manually, slowly guide the leaf for its entire stroke, 
do not push the leaf so it moves freely.

3.4   USE IN AN EMERGENCY

3.3 UNAUTHORISED USE

 

-

Any use other than the intended use is prohibited.

 

-

It is prohibited to install the automation outside of the limits set 
forth in the Technical data and the Installation requirements.

 

-

It is prohibited to install the automation along escape routes.

 

-

It is prohibited to install the automation to implement smoke 
and/or fire protection doors (fire doors).

 

-

It is prohibited to install the automation in areas that are at risk of 
explosion and/or fire: the presence of flammable gases or fumes 
poses a severe danger for safety (the product is not certified 
pursuant to directive 94/9/EC ATEX).

 

-

It is prohibited to power the system with energy sources other 
than those set forth.

 

-

It is prohibited to integrate unrelated commercial systems and/
or equipment, or employ them for uses that are not allowed by 
the respective manufacturers.

 

-

It is prohibited to use and/or install accessories that are not 
specifically approved by FAAC S.p.A..

 

-

It is prohibited to use the automation before having commis-
sioned the system.

 

-

It is prohibited to use the automation with faults/tampering 
which could jeopardise safety.

 

-

It is prohibited to use the automation with movable and/or fixed 
guards that have been tampered with or removed.

 

-

Do not expose the actuator to direct jets of water of any type 
and amount.

 

-

Do not expose the actuator to chemical or aggressive environ-
mental agents.

3.5 PRODUCT IDENTIFICATION

The product is identified by the plate (see 

2

).

Sales code
Product name
IDENTIFICATION NUMBER 
Month/Year of manuf Progressive 
number in production month.
Example:  0115 

0001

made in January 2015  S/N 1 

The leaf must comply with the dimensional and weight limits speci-
fied in the technical data.
Comply with the frequency of use limits indicated in the technical 
data.
Environmental phenomena, even occasional, such as ice, snow and 
strong wind may hinder correct operation of the automation and 
affect component integrity and may become a potential source of 
danger (see 

§

 Use in an emergency).

The limits of use in relation to the wind are described in detail in 

 Limits of use of S800 ENC in relation to the wind.

In the presence of a pedestrian door integrated in the leaf of the gate, 
motorised movement must be prevented when the pedestrian door 
is not closed.
S800 ENC is not designed as a protective system against intrusion.
S800 ENC must be connected to an electronic board FAAC for 230 V 
  motor control of swing gates, fitted with a BUS connection and slow-
down control at the limit switch.
The automation set-up requires necessary safety devices to be in-
stalled, which are identified by the installer after having carried out 
a proper risk assessment of the installation site.

In any malfunction, emergency or fault, disconnect the power sup-
ply of the automation.  If the conditions allow the leaf to be safely 
moved manually, use the MANUAL OPERATION; otherwise, keep the 
automation out of service until it is restored/repaired.
In case of a fault, the automation must be restored/repaired must 
only be carried out by the INSTALLER/MAINTENANCE TECHNICIAN.

Summary of Contents for S800 ENC

Page 1: ...S800 ENC...

Page 2: ...cit s sont la propri t de leurs fabricants respectifs Les clients peuvent faire des copies pour leur usage exclusif Ce manuel a t publi en 2016 Copyright FAAC S p A ab dem 2016 Alle Rechte vorbehalte...

Page 3: ...maynotbecom missioneduntilthefinalmachine intowhichitwillbeincorporated hasbeendeclared complaintwiththeprovisionsoftheabovementionedMachineDirective2006 42 EC Bologna 01 01 2016 CEO ANNEX 1 The limit...

Page 4: ...tions The results of the risk assessment conducted by FAAC S p A on the entire life cycle of the product has been considered when drafting the manual in order to implement effective risk reduction The...

Page 5: ...e automation components Do not modify the original components in any way Close off the work site even temporarily and prevent access tran sit EC countries must comply with the legislation that transpo...

Page 6: ...4 Positive stop fastenings 5 Instruction manual Followtheinstructionsonthepackage while handling it Use the forklift truck or pallet truck in observance of the safety rules to avoid risks of collisio...

Page 7: ...rth It is prohibited to integrate unrelated commercial systems and or equipment or employ them for uses that are not allowed by the respective manufacturers It is prohibited to use and or install acce...

Page 8: ...uce the maximum stroke maximum reduc tion 30 for opening and 30 for closing The limits of use of the positive stops in relation to the length and weight of the leaf are described in detail in 2 FAAC C...

Page 9: ...ler cap 7 By pass screws force adjustment 8 Service release lever 9 Positive stop fastenings 10 Installation support 11 Key INSTALLATION ACCESSORIES SUPPLIED SEPARATELY Foundation box 12 Cover 13 Remo...

Page 10: ...ng and closing stops to limit the leaf stroke The stops must be adequately sized and firmly secured to withstand the impact of the leaf The external mechanical stops are not required when using positi...

Page 11: ...he risk of electrocution Ensure there are no pipes near the excavations and drilling areas The electronic board must be housed in an enclosure which guarantees minimum IP 44 protection The board enclo...

Page 12: ...CTIVE EQUIPMENT Anchor the leaf to the lifting device with a rope or a suitable chain After removing the leaf place it on the ground or anchor it with a rope or chain to prevent it from tipping over 5...

Page 13: ...1 2 Position the grooved joint 8 2 Thenotchonthejointmustbecentredwiththecentrelineofthebracket and directed as shown in the figure When the bracket is placed on the box the joint must be centred on t...

Page 14: ...he service lever by more than one turn so as to prevent oil from leaking 4 Insertthespannerinthepinion 12 2 androtatethepinionuntil it stops in the closing direction of the leaf Then move it back appr...

Page 15: ...chieve the required tightening torque 15 6 11 Open and close the leaf manually to ensure it can be fully opened and closed manually If not ensure that all of the installation steps have been carried o...

Page 16: ...eaf movement screw B adjusts the force of anticlockwise leaf movement tighten to increase the force loosen to decrease the force 3 Set the protective caps back in place 17 1 CLOSURE OF THE BOX Close t...

Page 17: ...procedure until non emulsified oil comes out 6 Set the protective caps back in place 19 1 TOPPING UP THE OIL LEVEL 1 Remove the cap 19 3 Check the oil level it should be just below the cap 2 Top up if...

Page 18: ...tronic board enclosure 12 Checktheintegrityofthepowerandconnectioncablesandofthecableglands Check the integrity of the connectors and of the wiring 12 Checkthattherearenosignsofoverheating burns etc o...

Page 19: ...he lock 20 1 2 Insert the key and turn it one anti clockwise turn until it stops 20 2 then move the gate manually RESTORING AUTOMATIC OPERATION 1 Turn the key by one clockwise turn until it stops 20 3...

Page 20: ...ame of the wind Beaufort scale Wind speed km h 0 Calm 1 1 Light air 1 6 2 Light breeze 6 11 3 Gentle breeze 11 19 4 Moderate breeze 19 29 5 Fresh breeze 29 39 6 Strong breeze 39 50 7 Near gale 50 62 8...

Page 21: ...1 10 POS 11 1 10 POS 2 5 8 POS 3 5 8 POS 1 POS 3 POS 2 POS 6 POS 7 POS 11 POS 11 POS 4 POS 12 POS 5 POS 12 POS 8 POS 9 POS 9 POS 11 1 10 POS 9 2 10 POS 12 1 10 Translation of the original instruction...

Page 22: ...S800 ENC 20 532116 Rev A...

Page 23: ...S800 ENC 21 532116 Rev A...

Page 24: ...FAAC S p A Soc Unipersonale Via Calari 10 40069 Zola Predosa BOLOGNA ITALY Tel 39 051 61724 Fax 39 051 758518 www faac it www faacgroup com S800 ENC 22 532116 Rev A...

Reviews: