ENGLISH
ELECTRICAL CONNECTIONS
Connection of traditional
safety devices and
photocells
Enable in
1
st
level programming
Use with motors without a
BUS-2EASY encoder
Max load 24Vdc - 500mA
Connection of a pair of closing photocells and a pair of ope-
ning/closing photocells with
disabled
FAIL-SAFE safety device
and STOP
CONNECTION OF TRADITIONAL SAFETY DEVICES
ADDRESSING THE BUS-2EASY PHOTOCELLS
Important: the same address must be given to both
transmitter and receiver.
Make sure that there are not two or more photocell pairs
with the same address.
If you are not using any BUS-2EASY accessory, leave
free connector BUS-2EASY
PHOTOCELLS
BUS-2EASY
DL1
= Alignment
DL2
= BUS-2EASY/
power supply status
DS1
= Programming
dip-switches
Dip1
Dip2
Dip3
Dip4
Rif.
Type
OFF
OFF
OFF
OFF
B - C
OPENING
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
D
CLOSING
ON
OFF
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
OFF
OFF
ON
OFF
OFF
A
OPENING
and CLOSING
OFF
ON
OFF
ON
ON
ON
ON
ON
/
OPEN PULSE
The following table shows the programming operations of the dip-switch
inside the transmitter and the BUS 2-EASY photocells receiver.
With the E124 control unit, you can use both traditional
photocells (N.C. contact with relay) and/or photocells with
BUS-2EASY.