6
F
F
-
+
F
F
+
+
F
+
+
ENGLISH
PROGRAMMING
Programming is divided in two levels:
BASIC programming
ADVANCED programming
The programming phases are (see
Tab.
):
1. to access PROGRAMMING (
1A
or
1B
);
2. to show the set values and modify them, if you want.
Changing the values is effective immediately, while the final memorisation must be carried out
upon exiting programming
(
St
)
.
3. exit the programming by using
St
function. Select
Y
to SAVE the configuration you just performed, otherwise select
no
to EXIT WITHOUT
SAVING any changes.
You can
EXIT programming at anytime
:
press and hold
F
and then also
-
to switch directly to
St
.
F
+
-
This board also allows
programming using a PC
or
MAC
.
This programming requires connection to PC/MAC via USB cable and USB-B relevant port.
The programming SOFTWARE with relevant instructions, must be downloaded from the website
:
www.faacgroup.com
The programming using a PC/MAC, with the
default PASSWORD
does not inhibit the programming by board. The writing
PC
will be displayed
in correspondence with the modified values.
Notes
: when you modify the values by board the previous PC/MAC programming will be overwrote.
The default password is
0000.
The programming using a PC/MAC, with a modified PASSWORD (different from the default one), will inhibit the programming by board. If one
of the buttons is pressed, the display will show
PC
programming for 5 sec and changes will be allowed only by PC /MAC.
쐃
쐇
쐋
BASIC
PROGRAMMING
1A
.
PRESS
AND
HOLD
F
:
THE
FIRST
FUNCTION
APPEARS
Í
1
RELEASE
F
:
THE
FUNCTION
VALUE
IS
DISPLAYED
USING
+
OR
-
,
SCROLL
THE
AVAILABLE
VALUES
UNTIL
THE
THE
DESIRED
ONE
PRESS
F
:
TO
MOVE
TO
THE
NEXT
FUNCTION
Í
1
FUNCTION
St
(
LAST
BASIC
OR
ADVANCED
FUNCTION
)
ADV
ANCED
PROGRAMMING
1B
.
PRESS
AND
HOLD
F
AND
THEN
ALSO
+
:
THE
FIRST
FUNCTION
APPEARS
Í
1
RELEASE
THE
KEYS
:
THE
FUNCTION
VALUE
IS
DISPLAYED
SELECT
Y
TO
SAVE
THE
PROGRAMMING
OTHERWISE
SELECT
no
TO
EXIT
THE
PROGRAMMING
WITHOUT
SAVING
Í
1
THE
FUNCTION
IS
DISPLAYED
UNTIL
YOU
HOLD
Tab.
Programming phases.
Connector J13 – XF MODULE rapid connection
The control unit has an integrated 2-channel decoding system (DS, SLH, LC/RC) named OMNIDEC. This sy-
stem makes it possible to save – through an extra receiver module – XF433 or XF868 radio commands of the
same frequency, but of a different type (DS, SLH, LC/RC). It is possible to save both total opening (OPEN A)
and partial opening (OPEN B) of the automated system, up to a maximum of 256 channels.
Insert and remove the boards only after cutting power.
Summary of Contents for E124