21
ENGLISH
SIGNALLING ERRORS AND ALARMS
In case of
ERRORS
(conditions that stop gate operation) or
ALARMS
(conditions that do not compromise gate operation) it is possible to see
the number related to the warning.
These warnings will disappear in the following cycle only if the situation causing them is removed.
:KHQWKHUHLVDQ(5525WKH$/$50/('ZLOOJRRQVWHDG\:KHQDQ$/$50LVWULJJHUHGWKH$/$50/('VWDUWVWRÀDVK
By simultaneously pr and - the display will show corresponding error number.
N°
ERROR
SOLUTION
0 1
Board broken
Replace the board
02
Thermal protection active
Wait for the board to cool down, check for overloads
03
Motor 1 faulty
Check that the motor works and that the wiring is not interrupted or damaged
04
Motor 2 faulty
0 5
Invalid SETUP
Repeat board SETUP
0 8
BUS-2EASY
device error
Ensure that no two pairs of devices have the same address.
0 9
BUS-2EASY
output
short-circuit
Check the connections of the connected and entered
BUS-2EASY
devices
1 0
Motor 1 limit switch error
Check the limit switch connections for motor 1
1 1
Motor 2 limit switch error
Check the limit switch connections for motor 2
1 2
BUS-2EASY
call
Ensure that the BUS devices are operating correctly and, if necessary, repeat BUS device acquisition
1 3
FAIL SAFE
Check that the safety devices (photocells) are operating correctly
1 4
Configuration error
Check that the board is configured correctly (basic and advanced programming) and, if necessary, repeat SETUP
15
Movement timeout reached
Check that the motors are blocked; check that any limit switches are activated correctly and that the mechanical stops
are present.
16
Deep sleep
The board is in advanced energy-saving mode. No action required.
1 7
Motor 1 encoder fault
Check the connections or replace motor 1 encoder
1 8
Motor 2 encoder fault
Check the connections or replace motor 2 encoder
1 9
Incorrect memory data
Repeat
BUS-2EASY
device entry and/or re-program the board
4 5
Battery operation
No action required.
9 3
High absorption at +24V
Check that absorption by the accessories connected is within permitted limits
N°
ALARM
Solution/Description
2 0
Obstacle on MOTOR 1 (only with en-
coder)
Remove any possible obstacle on leaf 1
2 1
Obstacle on MOTOR 2 (only with en-
coder)
Remove any possible obstacle on leaf 2
22
MOTOR 1 current limited
Check the force set on motor 1
23
MOTOR 2 current limited
Check the force set on motor 2
2 5
LOCK 1 output short-circuit
Remove the cause of the short-circuit
2 6
LOCK 2 output short-circuit
Remove the cause of the short-circuit
2 7
Nr. of consecutive obstacles exceeded
during opening
Remove any possible obstacle.
Should the problem persist, repeat SETUP
2 8
Nr. of consecutive obstacles exceeded
during closing
Remove any possible obstacle.
Should the problem persist, repeat SETUP
3 0
XF
radio code memory full
Cancel the radio codes that are not being used using the PC program or use an additional DEC/MINIDEC/
RP module
3 1
Tampering alarm
Movement was performed with automation in status
St
=
00
or
01
. Perform a manoeuvre cycle.
32
Emergency active
Check that the emergency input is not active (configuration only possible from PC/Mac)
3 5
TIMER active and TIMER function operating: TIMER function is operating
4 0
Service request
Contact the installer for maintenance
5 0
The HOLD POSITION is operating (active
on PC/MAC )
HOLD POSITION function is operating
6 0
TIMER active and error in TIMER data
Reload a correct TIMER configuration with the PC/MAC programme
6 2
Loss of time and date on the board (only
if the TIMER is operating)
Reload the time and date with the PC/MAC programme and replace the BAT1 - CR2032 buffer battery
6 3
JOLLY TIMER is activated
JOLLY TIMER is enabled by terminal board J3
6 4
TIMER DISABLED is operating
TIMER is disabled by terminal board J3