Channel list edition 1 for EP104 version 4.08
General configuration channels
No.
Name
Range
Factory
Setting
S
C033 Pulse/hold-to-run
0 - 5
5
0
Open and close with hold-to-run and load guard inactive
1
Open with pulse and close with hold-to-run and load guard active
2
Open with hold-to-run and close with pulse and load guard active
3
Open and close with pulse and load guard active
4
Open and close with hold-to-run and load guard active
5
Service mode, only internal open/close buttons with hold-to-run.
Enables L001/2 to be set to 4, operation without limit switch. Load guard inactivated
C063
Reverse priority during movement
0 – 3
1
0
None
1
Open
2
Close
3
Open and close