CHANNEL LIST DAAB AUTOMATIC CONTROL UNIT EP104 4.08
30
Channel list edition 1 for EP104 version 4.08
No.
Name
Range
Factory
Setting
o230*
Alarm delay. Alarms in channels o231 - o242 must be
active this time to give an output signal.
0.00-9.59 minutes
0.00
o231*
Alarm for faulty safety edge.
0 - 1
0
0
Disabled
1
Constant signal
o232*
Alarm for uncritical error message in display
0 - 1
0
0
Disabled
1
Constant signal
o233*
Alarm if stop circuit interrupted
0 - 1
0
0
Disabled
1
Constant signal
o234*
Alarm if door open
0 - 1
0
0
Disabled
1
Constant signal
o235*
Alarm if door is in mid position
0 - 1
0
0
Disabled
1
Constant signal
o236*
Alarm if door is in closed position
0 - 1
0
0
Disabled
1
Constant signal
o237*
Alarm if vehicle loop 1 is activated
0 - 1
0
0
Disabled
1
Constant signal
o238*
Alarm if vehicle loop 2 is activated
0 - 1
0
0
Disabled
1
Constant signal
o239*
Alarm if photocell interrupted
0 - 1
0
0
Disabled
1
Constant signal
o242*
Alarm for uncritical error message in display
0 - 1
0
0
Disabled
1
Constant signal
o283
Selection of contact function for output
1 - 2
1
1
Normally open, NO
2
Normally closed, NC
* = Only when o200 is set to 4.