CHANNEL LIST DAAB AUTOMATIC CONTROL UNIT EP104 4.08
56
Channel list edition 1 for EP104 version 4.08
Error messages
Grey background means that the automatic control unit must be restarted (power off) in order to reset the error message.
Error
code
Meaning
Possible cause
EP-1
Not an error code – indicates the type of EP104
in use
EP-2
Not an error code – indicates the type of EP104
in use
E000
No error, shown to acknowledge a change in the
service channel.
E003
Limited running time exceeded
Gears slipping? Check C403
E008
Momentary loss of 24 V
Momentary 24VDC short circuit?
E015
Loss of mains power
Has there been a power failure? Mains power switch
operated?
E016
Momentary loss of mains power
Short mains power failure less than 0,5 seconds
E017
Safety edge or load guard triggered five times in
succession
It something preventing the door reaching the closed
position?
E020
Voltage too high in safety circuit
The voltage measured by the automatic control unit is too
high.
E021
Voltage too low in safety circuit
Check external safety circuit, terminal 7-12
E025
Incorrect setting for personal protection, motor 1
Check C200 and C230, the load guard cannot be disabled
with personal protection activated. Check C211, it cannot
be longer than 0.06 seconds. C212 cannot be longer than 2
seconds. C493 cannot be longer than 0.20 seconds.
E026
Incorrect setting for personal protection, motor 2
Check C200 and C240, the load guard cannot be disabled
with personal protection activated. Check C211, it cannot
be longer than 0.06 seconds. C212 cannot be longer than 2
seconds. C493 cannot be longer than 0.20 seconds.
E027
Incorrect setting for motor protection, low limit
inactive
If C202 is not set to 4 C201 may not be set to 1. C201 is only
used with a frequency converter.
E028
Brake selected when using a frequency converter
Check that C495/C496 is set to 0.
E032
Limit switch L.O1 has lost its position
Is the limit switch cam bypassing the switch? Loose
connection in switch?
E033
Limit switch L.C1 has lost its position
Is the limit switch cam bypassing the switch? Loose
connection in switch?
E034
Limit switch L.O2 has lost its position
Is the limit switch cam bypassing the switch? Loose
connection in switch?
E035
Limit switch L.C2 has lost its position
Is the limit switch cam bypassing the switch? Loose
connection in switch?
E040
Invalid selection in the service channel
E044
Hidden channels shown
E046
Opening counter reset
E047
Factory reset of all channels
E048
Error code list reset
E050
Unknown circuit board, EP104 or Light not fully
equipped
Contact FAAC Nordic AB
E051
Incorrect software, full version programmed in
EPLight
Contact FAAC Nordic AB
E052
Incorrect software, EPLight software programmed
into a fully equipped EP104
Contact FAAC Nordic AB
E116
No safety edge acknowledgement
Only applies to up-and-over control, fault in safety edge?
Correct run-on time?
E141
SE.O2 is disabled when C104=3