d161
Type of control signal when activated
1 - 2
1
1
Pulse
2
Constant signal when loop is activated
d162
Half operation
1 - 3
3
1
Motor 1
2
Motor 2
3
Motors 1 and 2
d163
Limited opening
0 - 1
0
0
Disabled
1
Opening for the time set in channels C412 and C414 or L116 and L126
d170
Allows the opening function, via LOOP1, using a
programmable input.
0 - 6
0
0
Disabled, normal opening/closing function. (Programmable input has no function for LOOP1)
1
Opening possible only if there is a signal at programmable input 1
2
Opening possible only if there is a signal at programmable input 2
3
Opening possible only if there is a signal at programmable input 3
4
Opening possible only if there is a signal at programmable input 4
5
Opening possible only if there is a signal at programmable input 5
6
Opening possible only if there is a signal at programmable input 6
d175
Opening via loop after activation for the set time, the
loop will not open the gate until it has been activated
for the set time.
0.0-9.0 sec
0.0
d190
Interlock opening
0 - 1
0
0
Disabled
1
Sends a normal open signal to the remote door