CHANNEL LIST DAAB AUTOMATIC CONTROL UNIT EP104 4.08
35
Channel list edition 1 for EP104 version 4.08
Programmable output 4
No.
Name
Range
Factory Setting
o400
Function of output 4
0 - 4
0
0
Disabled
1
Position indication/Movement/Warning. Signal as configured in o410 – o422
2
Presence detection/Direction sensing. Signal as configured in o491
3
Lock
4
Alarm output Signal as configured in o430 – o442
o410
Open position
0 - 2
0
0
Disabled
1
Constant signal
2*
Flashing signal, invalid selection for DB410
o411
Mid position
0 - 2
1
0
Disabled
1
Constant signal
2*
Flashing signal, invalid selection for DB410
o412
Closed position
0 - 2
1
0
Disabled
1
Constant signal
2*
Flashing signal, invalid selection for DB410
o413
Movement
0 - 7
0
0
Disabled
1
Constant signal in the opening movement
2
Constant signal in the closing movement
3
Constant signal in the opening and closing movement
4
No signal during movement, used in combination with o410, o411 and o412.
5*
Flashing signal in the opening movement, invalid selection for DB410
6*
Flashing signal in the closing movement, invalid selection for DB410
7*
Flashing signal in the opening and closing movement, invalid selection for DB410
o414
Delayed switch-off Switch off after the specified time For
example to switch off lighting a specified time after closing
0.00-9.59 minutes
0.00
o420
Warning time before start
0.00-9.59 minutes
0.00
o421
Warning function in combination with o420
1 - 8
2
1
Constant signal before automatic closing
2
Constant signal before park and automatic closing
3
Constant signal before close signal, park and automatic closing
4
Constant signal before all signals
5*
Flashing signal before automatic closing, invalid selection for DB410
6*
Flashing signal before park and automatic closing, invalid selection for DB410
7*
Flashing signal before close signal, park and automatic closing, invalid selection for DB410
8*
Flashing signal before all signals, invalid selection for DB410
* WARNING! This setting is possible, but NOT permitted for DB410! Selecting it means that the relay output will cease