CHANNEL LIST DAAB AUTOMATIC CONTROL UNIT EP104 4.08
14
Channel list edition 1 for EP104 version 4.08
General time channels.
No.
Name
Range
Factory
Setting
C401** Running time readout, motor 1
000-999 seconds
C402** Running time readout, motor 2
000-999 seconds
C403** Setting limited running time (Not used with encoder)
001-999 seconds
001
C412** Set limited opening, motor 1 with limit switch
00.3-99.9 seconds
05.0
C414** Set limited opening, motor 2 with limit switch
00.3-99.9 seconds
05.0
C422** Run-on time following limit switch open, motor 1
0.00-7.99 seconds
0.00
C423** Run-on time following limit switch closed, motor 1
0.00-7.99 seconds
0.00
C432** Run-on time following limit switch open, motor 2
0.00-7.99 seconds
0.00
C433** Run-on time following limit switch closed, motor 2
0.00-7.99 seconds
0.00
S
C436 Type of stop during run-on time when closing,
subordinated to C448 and C449
0 - 3
3
0
Time
1
Time or load guard
2
Time or safety edge
3
Time, load guard or safety edge
S
C448 Safety edge reverse during run-on time in the closing
movement, C423, C433, L117, L127
0 - 2
2
0
Function disabled
1
Safety edge reverse during run-on time
2
Safety edge reverse during run-on time and during the time in C492
S
C449 Reversing during run-on time with triggered load
guard, C423, C433, L117, L127
0 - 1
1
0
Disabled
1
Reversing in closing movement
C460
Delay of open motor 2 and close motor 1. Used with
magnetic locks or if the door halves overlap
0.1-9.9 seconds
0.1
C470
Delay before first motor starts, used for magnetic
locks that need to lose residual magnetisation
0.00-0.99 seconds
0.00
S
C492 Reverse delay if PHOTO, LOOP1, LOOP2 or
control signal are activated.
0.1-4.0 seconds
0.8
S
C493 Reverse delay if safety edge or load guard are activated 0.03-2.00 seconds
0.10
S
C494 Closing time after activated protection function, safety
edge or load protection, in opening motion.
0.1-2.0 seconds
1.0
C495
Engagement time for brake, motor 1
00, 10-50 ms
00
C496
Engagement time for brake, motor 2
00, 10-50 ms
00
** = Only displayed if L001 and/or L002 are set to 2 or 3.