CHANNEL LIST DAAB AUTOMATIC CONTROL UNIT EP104 4.08
45
Channel list edition 1 for EP104 version 4.08
Programmable input 2
No.
Name
Range
Factory Setting
P200
Channels in programmable input 2
0 - 1
1
0
Disabled
1
Enabled
P260
Control function
0-5
2
0
Disabled
1
Open
2
Close
3
Stop
4
Open/close
5
Open/stop/close
S
P261 Type of control signal when activated
1 - 2
1
1
Pulse (hold-to-run mode not possible)
2
Signal for as long as the input is activated
P262
Half operation
1 - 3
3
1
Motor 1
2
Motor 2
3
Motors 1 and 2
P263
Limited opening
0 - 1
0
0
Disabled
1
Opening according to set time in channel C412/C414 or number of degrees in L116/L126 if encoder
is used.
P270
Motor lock
0 - 1
0
0
Disabled
1
The barrier cannot be operated without a signal at programmable input 2. If the signal disappears the
barrier is stopped.
P275
Opening via input after activation during set time, input will
not open the barrier until it has been activated for the set
time.
0.0-9.9 seconds
0.0
P280
Keep open
0 - 2
0
0
Disabled
1
Automatic closing disabled after the input is activated, reset by another control signal
2
Automatic closing disabled by a constant signal
P290
Interlock opening
0 - 1
0
0
Disabled
1
Opens the local door if P260 is set to open, and passes the signal on to the remote door
P296
Blocking disabled for local and remote doors. Works only
with a constant signal.
0 - 1
0
0
Disabled
1
Active
P298
Automatic closing disabled for remote door Only works if
there is a constant signal
0 - 1
0
0
Disabled
1
Active