CHANNEL LIST DAAB AUTOMATIC CONTROL UNIT EP104 4.08
32
Channel list edition 1 for EP104 version 4.08
Programmable output 3
No.
Name
Range
Factory Setting
o300
Function of output 3
0 - 4
1
0
Disabled
1
Position indication/Movement/Warning. Signal as configured in o310 – o322
2
Presence detection/Direction sensing. Signal as configured in o391
3
Lock
4
Alarm output Signal as configured in o330 – o342
o310
Open position
0 - 1
1
0
Disabled
1
Constant signal
o311
Mid position
0 - 1
0
0
Disabled
1
Constant signal
o312
Closed position
0 - 1
0
0
Disabled
1
Constant signal
o313
Movement
0 - 4
4
0
Disabled
1
Constant signal in the opening movement
2
Constant signal in the closing movement
3
Constant signal in the opening and closing movement
4
No signal during movement, used in combination with o310, o311 and o312.
o314
Delayed switch-off Switch off after the specified time For
example to switch off lighting a specified time after closing
0.00-9.59 minutes
0.00
o320
Warning time before start
0.00-9.59 minutes
0.00
o321
Warning function in combination with o320
1 - 4
2
1
Constant signal before automatic closing
2
Constant signal before park and automatic closing
3
Constant signal before close signal, park and automatic closing
4
Constant signal before all signals
o322
Function during warning time
1 - 2
1
1
Output signal disabled during warning in other output
2
Signal as configured in o310-o313