FAAC DAAB EP104 V4.08 Manual Download Page 1

The installer's guide for EP104

For complete instructions refer to the instruction manual of EP104 
and other documentation that accompanies delivery

CHANNEL LIST
DAAB CONTROL UNIT EP104 V4.08

FAAC Nordic AB

BOX 125, SE-284 22 PERSTORP SWEDEN,  

+46 435 77 95 00,  

 [email protected]

www.faac.se

Revision: 8

Summary of Contents for DAAB EP104 V4.08

Page 1: ...ctions refer to the instruction manual of EP104 and other documentation that accompanies delivery CHANNEL LIST DAAB CONTROL UNIT EP104 V4 08 FAAC Nordic AB BOX 125 SE 284 22 PERSTORP SWEDEN 46 435 77...

Page 2: ...cable Cables outside the enclosure must be securely fixed to the surrounding structure They must not hang loose and there must be no possibility of them catching on passing objects High current The po...

Page 3: ...shown on the left make the following changes EP104 1 Swap the cable at X12 L1 1 with X12 L1 CUR1 EP104 2 Remove the cable between X11 L2 1 and X4 L2 2 Swap the cable at X12 L1 1 with X12 L1 CUR1 Swap...

Page 4: ...diagram below The maximum number of safety edges connected in series with an impedance of 8 2 k is six per input Note that the impedance used for a safety edge must be checked and entered into the EP...

Page 5: ...are the same buried pipe as the motor power supply DB405 Motor 1 DB405 Motor 2 EP104 14 17 1 2 3 1 2 3 34 L O1 L O2 GND 24V 24V GND GND L OUT L OUT 24V 13 24V 16 Connecting a mechanical limit switch m...

Page 6: ...3 34 35 36 37 38 24VDC 300mA Safety edge 1 closing movement SE C1 Safety edge 2 closing movement SE C2 Stop input 1 Stop input 2 Stop input 3 Encoder output limit switch open motor 1 Limit switch clos...

Page 7: ...SE O2 for a safety edge while opening Variable impedance 1 0 9 9 k power capability at least 0 5 W Safety circuit Maximum resistance 3 in total throughout the safety circuit Cable length 0 75 mm2 max...

Page 8: ...hannels so they cannot be changed The S symbol means that the channel is a safety setting and any change in value must be documented in the log book with a name and date General C channels General rea...

Page 9: ...pulse and close with hold to run and load guard active 2 Open with hold to run and close with pulse and load guard active 3 Open and close with pulse and load guard active 4 Open and close with hold...

Page 10: ...th safety edges reverse stop an active motor 2 SE C1 and SE O1 must be connected to motor 1 SE C2 and SE O2 must be connected to motor 2 The safety edge function is attached to the motor concerned 3 S...

Page 11: ...e according to set value in C135 2 Resistance between 5 kohm and 15 kohm S C132 Reverse stop with activated safety edge SEO1 1 2 1 1 Reverse 2 Stop S C133 Control of external protection connected to S...

Page 12: ...3 0 5 0 seconds 5 0 S C230 AB Set motor power readout for personal protection motor 1 0 00 and 0 12 0 35 kW 0 20 C231 B Motor power readout motor 1 0 00 1 99 kW S C232 B Set load guard limit for motor...

Page 13: ...isabled when both halves are in run on or disengagement angle 1 Activated according to C340 C342 Safety function in opening movement 0 4 0 0 Disabled 1 Reverse to fully closed 2 Stop with automatic re...

Page 14: ...afety edge 3 Time load guard or safety edge S C448 Safety edge reverse during run on time in the closing movement C423 C433 L117 L127 0 2 2 0 Function disabled 1 Safety edge reverse during run on time...

Page 15: ...OOP2 must first be activated simultaneously signal when either PHOTO or LOOP2 is clear 07 Presence detection PHOTO LOOP1 and LOOP2 must first be activated simultaneously signal when either PHOTO LOOP1...

Page 16: ...abled 1 Automatic control unit no 1 in communication 2 Automatic control unit no 2 in communication Service channels No Name Range Factory Setting C900 Service channel for service personnel only Rando...

Page 17: ...CHANNEL LIST DAAB AUTOMATIC CONTROL UNIT EP104 4 08 17 Channel list edition 1 for EP104 version 4 08...

Page 18: ...d140 Safety function in closing movement 0 4 1 0 Disabled 1 Reverse 2 Stop with automatic restart of automatic closing 3 Stop without automatic restart of automatic closing wait for new control signal...

Page 19: ...ng function Programmable input has no function for LOOP1 1 Opening possible only if there is a signal at programmable input 1 2 Opening possible only if there is a signal at programmable input 2 3 Ope...

Page 20: ...in closing movement 0 4 1 0 Disabled 1 Reverse 2 Stop with automatic restart of automatic closing 3 Stop without automatic restart of automatic closing wait for new control signal 4 Safety only in op...

Page 21: ...nction Programmable input has no function for LOOP2 1 Opening possible only if there is a signal at programmable input 1 2 Opening possible only if there is a signal at programmable input 2 3 Opening...

Page 22: ...ion time at photocell and vehicle loops from 100 0Hz 0 5 9 9 Seconds 1 0 F008 Low speed frequency for opening movement 5 20 Hz 10 F009 Low speed frequency for closing movement 5 20 Hz 10 F012 Opening...

Page 23: ...9 M10 with pulleys 71 71 and motor 2800 rpm ratio 1485 1 F031 Measured ratio motor 1 Only when F030 0 0 9999 F040 Choice of ratio for motor 2 0 9 0 0 Not selected in this position the motor only rotat...

Page 24: ...half at a time can be run C033 must be set to 5 L110 Placement of motor 1 viewed from the motor side 0 2 1 0 Disabled 1 Left 2 Right L111 Position angle readout motor 1 000 360 degrees L112 Open posit...

Page 25: ...0 degrees 45 L127 Angle for the disconnection of safety edges load guard and photocells from the end of the closing movement motor 2 in combination with C436 C341 and C448 0 30 degrees 0 L128 Angle fo...

Page 26: ...0 Disabled 1 Constant signal in the opening movement 2 Constant signal in the closing movement 3 Constant signal in the opening and closing movement 4 No signal during movement used in combination wit...

Page 27: ...d 1 Constant signal o134 Alarm if door open 0 1 0 0 Disabled 1 Constant signal o135 Alarm if door is in mid position 0 1 0 0 Disabled 1 Constant signal o136 Alarm if door is in closed position 0 1 0 0...

Page 28: ...er PHOTO or LOOP2 is clear 07 Presence detection Signal when PHOTO LOOP1 and LOOP2 are activated remains until either PHOTO LOOP1 or LOOP2 is clear 08 Presence detection Signal when either LOOP1 or LO...

Page 29: ...ant signal in the opening movement 2 Constant signal in the closing movement 3 Constant signal in the opening and closing movement 4 No signal during movement used in combination with o210 o211 and o2...

Page 30: ...ed 1 Constant signal o234 Alarm if door open 0 1 0 0 Disabled 1 Constant signal o235 Alarm if door is in mid position 0 1 0 0 Disabled 1 Constant signal o236 Alarm if door is in closed position 0 1 0...

Page 31: ...er PHOTO or LOOP2 is clear 07 Presence detection Signal when PHOTO LOOP1 and LOOP2 are activated remains until either PHOTO LOOP1 or LOOP2 is clear 08 Presence detection Signal when either LOOP1 or LO...

Page 32: ...nstant signal in the opening movement 2 Constant signal in the closing movement 3 Constant signal in the opening and closing movement 4 No signal during movement used in combination with o310 o311 and...

Page 33: ...d 1 Constant signal o334 Alarm if door open 0 1 0 0 Disabled 1 Constant signal o335 Alarm if door is in mid position 0 1 0 0 Disabled 1 Constant signal o336 Alarm if door is in closed position 0 1 0 0...

Page 34: ...er PHOTO or LOOP2 is clear 07 Presence detection Signal when PHOTO LOOP1 and LOOP2 are activated remains until either PHOTO LOOP1 or LOOP2 is clear 08 Presence detection Signal when either LOOP1 or LO...

Page 35: ...ening movement invalid selection for DB410 6 Flashing signal in the closing movement invalid selection for DB410 7 Flashing signal in the opening and closing movement invalid selection for DB410 o414...

Page 36: ...y 0 1 0 0 Disabled 1 Constant signal o433 Alarm if stop circuit interrupted 0 1 0 0 Disabled 1 Constant signal o434 Alarm if door open 0 1 0 0 Disabled 1 Constant signal o435 Alarm if door is in mid p...

Page 37: ...er PHOTO or LOOP2 is clear 07 Presence detection Signal when PHOTO LOOP1 and LOOP2 are activated remains until either PHOTO LOOP1 or LOOP2 is clear 08 Presence detection Signal when either LOOP1 or LO...

Page 38: ...ant signal in the opening movement 2 Constant signal in the closing movement 3 Constant signal in the opening and closing movement 4 No signal during movement used in combination with o510 o511 and o5...

Page 39: ...d 1 Constant signal o534 Alarm if door open 0 1 0 0 Disabled 1 Constant signal o535 Alarm if door is in mid position 0 1 0 0 Disabled 1 Constant signal o536 Alarm if door is in closed position 0 1 0 0...

Page 40: ...er PHOTO or LOOP2 is clear 07 Presence detection Signal when PHOTO LOOP1 and LOOP2 are activated remains until either PHOTO LOOP1 or LOOP2 is clear 08 Presence detection Signal when either LOOP1 or LO...

Page 41: ...ant signal in the opening movement 2 Constant signal in the closing movement 3 Constant signal in the opening and closing movement 4 No signal during movement used in combination with o610 o611 and o6...

Page 42: ...d 1 Constant signal o634 Alarm if door open 0 1 0 0 Disabled 1 Constant signal o635 Alarm if door is in mid position 0 1 0 0 Disabled 1 Constant signal o636 Alarm if door is in closed position 0 1 0 0...

Page 43: ...er PHOTO or LOOP2 is clear 07 Presence detection Signal when PHOTO LOOP1 and LOOP2 are activated remains until either PHOTO LOOP1 or LOOP2 is clear 08 Presence detection Signal when either LOOP1 or LO...

Page 44: ...L126 if encoder is used P170 Motor lock 0 1 0 0 Disabled 1 The barrier cannot be operated without a signal at programmable input 1 If the signal disappears the barrier is stopped P175 Opening via inpu...

Page 45: ...is used P270 Motor lock 0 1 0 0 Disabled 1 The barrier cannot be operated without a signal at programmable input 2 If the signal disappears the barrier is stopped P275 Opening via input after activat...

Page 46: ...is used P370 Motor lock 0 1 0 0 Disabled 1 The barrier cannot be operated without a signal at programmable input 3 If the signal disappears the barrier is stopped P375 Opening via input after activat...

Page 47: ...otor lock 0 1 0 0 Disabled 1 The barrier cannot be operated without a signal at programmable input 4 If the signal disappears the barrier is stopped P475 Opening via input after activation during set...

Page 48: ...414 or number of degrees in L116 L126 if encoder is used P570 Motor lock 0 1 0 0 Disabled 1 The barrier cannot be operated without a signal at programmable input 5 If the signal disappears the barrier...

Page 49: ...y function in opening movement 0 4 1 0 Disabled 1 Reverse to fully closed 2 Stop with automatic restart of automatic closing 3 Stop wait for new control signal or time in C520 and then automatic closi...

Page 50: ...0 Disabled 1 Automatic closing disabled after the input is activated reset by another control signal 2 Automatic closing disabled by a constant signal P690 Interlock opening 0 1 0 0 Disabled 1 Opens t...

Page 51: ...CHANNEL LIST DAAB AUTOMATIC CONTROL UNIT EP104 4 08 51 Channel list edition 1 for EP104 version 4 08...

Page 52: ...163 Limited opening 0 1 0 0 Disabled 1 Time opening according to set time in channel C412 C414 or number of degrees in L116 L126 if encoder is used r170 Disable operation at wireless input 1 0 6 0 0 D...

Page 53: ...ening 0 1 0 0 Disabled 1 Time opening according to set time in channel C412 C414 or number of degrees in L116 L126 if encoder is used r270 Disable operation at wireless input 2 0 6 0 0 Disabled normal...

Page 54: ...ening 0 1 0 0 Disabled 1 Time opening according to set time in channel C412 C414 or number of degrees in L116 L126 if encoder is used r370 Disable operation at wireless input 3 0 6 0 0 Disabled normal...

Page 55: ...ening 0 1 0 0 Disabled 1 Time opening according to set time in channel C412 C414 or number of degrees in L116 L126 if encoder is used r470 Disable operation at wireless input 4 0 6 0 0 Disabled normal...

Page 56: ...ing for personal protection motor 2 Check C200 and C240 the load guard cannot be disabled with personal protection activated Check C211 it cannot be longer than 0 06 seconds C212 cannot be longer than...

Page 57: ...inuous For more troubleshooting tips see the instruction manual for the vehicle detector E319 Error in loop 2 E614 Communication error Correct polarity in communication cables Break in communication c...

Page 58: ...not change to low during the external test Check that the safety edge is functional if the safety edge is not functional set channel C113 to 0 E962 SE C2 did not change to low during the external test...

Page 59: ...ll not close but it will open The PHOTO LED should be on Are any safety edge indications on They should normally be off Suspect an incorrect connection to the safety edge Alternatively an adjustment m...

Page 60: ......