BARRIER CONFIGURATION
1. Power
Slave
barrier The board turns on. The
display reads in sequence:
-
firmware version (2 digits separated by a point)
-
SO
flashing if a set-up or the automation status
is requested
2. Access the Basic programming and set:
-
cF
depending on the arm configuration and length
-
Ct
=
SL
for configuring the board as
Slave.
3. Check the status of the LEDs on the board:
LED DL7 (Red)
Master
-
Slave
synchronisation absent or the line
is short circuited.
LED DL3 (Green)
Master
-
Slave
synchronisation present.
4. Check the direction of travel (see the chapter §
10.2). The barrier must not be in manual func-
tioning mode.
5. Start up (see the chapter § 6).
During the set-up the
Master
board controls the
Slave
board and the two arms move with a synchronous
movement.