momentarily and checking the change of status of the
input. If the test fails the electronic board does not
command the movement.
EXTERNAL LOOPS
!
The magnetic loop detectors must not be used to
detect pedestrians, cycles and motorbikes. If it
necessary to detect them, other devices such as
photocells are needed.
(
32
) Connect the magnetic detectors to terminal
boards J10 (
LOOP 1
) or J13 (
LOOP 2
).
LOOP 1
Opening coil NO contact
Connect a detector that, when the contact is closed (loop
engaged), commands the opening
LOOP 2
Transit coil NO contact
Connect a detector that, when the contact is closed (loop
engaged), works according to the set functioning logic:
all logics, except P
As long as the loop is engaged,
it prevents closing. If the loop is engaged during the
closing, it commands the inversion on opening.
only in logic P
The loop commands the closing at the
disengagement. If the loop is engaged during the
closing, it commands the stop (disengage the loop to
complete the closing)
BUS DEVICES
If no BUS 2easy devices are used, leave the BUS 2easy
terminal board free.
See the chapter § 8.4 for the connection and
orientation.
OUT
OUTPUTS
Do not exceed 100mA max load for each output.
Open Collector Outputs: the activation of the output
and its polarity can be configured by Advanced pro-
gramming.
OUT
active
OUT
not active
NO polarity
0 V
"
open circuit
NC polarity
open circuit
0 V
"
(
33
) Connect the devices required to terminal
block J20.
24 V
"
FLASHING LIGHT
See the chapter
§
8.1 for the connection.
MOTOR
(
34
) The motor wire is connected from the factory
for a RH barrier.
Invert the wires if a LH barrier is being installed.