48
B614
52
532297 - Rev.D
11.4 FUSE REPLACEMENT
1. (
48
) Remove the fuse F1 cover by gently pry
it off with a screwdriver.
2. Remove the fuse
3. Plug in the new fuse.
4. Replace the fuse cover.
!
Only use a T5A UL approved (delayed) fuse.
11.5 OPERATIONAL PROBLEMS
10
Troubleshooting
CONDITION
FINDING SOLUTIONS
The barrier does not per-
form the SET-UP
The barrier does NOT
OPEN
check the automation is not released
check there is power
check the motor and encoder con-
nection
The barrier CLOSES rather
than OPENING and vice
versa.
invert the phases in the motor connec-
tion and perform a SET-UP
The barrier makes very
slow movements
check the force set
check the balancing of the arm
check the parameter
cF
has been set in
accordance with the arm length
if the barrier is being battery operated
make sure the battery is charged.
The barrier moves irre-
gularly
check the motor connection and make
sure that the encoder is working cor-
rectly
The barrier does NOT
OPEN
check the automation is not released
check the motor direction of travel
The barrier does NOT
CLOSE
check the automation is not released
check the motor direction of travel
Check the LED status of the controls,
loops, safety devices and
EMER
are
not active
The barrier does NOT
OPEN and does NOT
CLOSE
check the automation is not released
Check the status of the
STOP
LED is
not active
check the motor and encoder con-
nection