background image

17

ENGLISH

ENGLISH

This control unit can be installed in boxes E, L and LM.  Before
securing the card in the box, fit the supplied support feet (long
for  mod. E, short for models L and LM) in the 3 S-holes (Fig.20).

5.1.1. 844 T  ELECTRONIC CONTROL UNIT

TABLE 2

844 T TECHNICAL SPECIFICATIONS

Power supply

400V 3ph+N (+6 -10 %) 50Hz

Motor max load

950 W

Accessories power supply

2 4 V d c

Accessories max load

500 mA

Warning light power supply

24V~ (5W max)

A m b i e n t   t e m p e r a t u r e   r a n g e

- 20°C + 55°C

Fuses

transformer primary winding

accessories

Quick-fit plugs

 - for decoding cards or RP receivers -

Inputs

OPEN/PART OPEN/STOP/CLOSURE SAFETY DEVICES/

LIMIT-SENSORS

warning light

Outputs

flashing light

m o t o r

24Vdc accessories power supply

 pause time (5-10-15-30-60-120-180 sec.)

Fig. 19

TF1

RL7

RL6

RL8

F1

F2

SW1

DS1

J1

J2

J3

J4

J5

A     B  STOP  FSW  FCC  FCA

LK1

F1

SW1

J1

Led

LK1

J2

J5

RL6

RL8

RL7

J3

J4

DS1

F2

4.4.2. STEEL RACK TO BE BOLTED (Fig. 15)

1) Manually place the leaf in closed

position.

2) Rest the first section of the rack

level on the pinion gear and insert
the spacer between the rack and
the gate, locating it in the upper
part of the slot.

3) Mark the drilling point on the gate.

Drill Ø 6.5 mm. and tap with a Ø 8
mm. taps. Tighten the bolt.

4) Move the gate by hand, checking whether the rack rests on

the pinion and repeat operations at point 3.

5) Position another rack element next to the previous one, using

a section of rack as in Fig. 17.

6) Move the gate by hand and execute the securing operations

as done for the first element, carrying on until you have
covered the entire gate.

Fig. 15

Fig. 16

Fig. 17

Notes on the rack

As the gate moves, make sure that no rack elements lose
contact with the pinion.

Do not, repeat do not, weld the rack elements either to the
spacer or to each other.

After installing the rack, to ensure correct meshing with the
pinion gear, we advise you to lower the position of the
gearmotor by approximately 1.5 mm
(Fig.18).

Manually check that the gate
reaches the mechanical limit stops
correctly, and that there is no fric-
tion during travel.

Do not apply grease or other lubri-
cants between rack and pinion.

5. START-UP

5.1. CONNECTION TO ELECTRONIC CONTROL UNIT

Ü

Before attempting any work on the control unit (connections,

programming, maintenance), always turn off power supply.

Observe points 10, 11, 12, 13 and 14 of the GENERAL SAFETY
OBLIGATIONS.
Observing the instructions in Fig.3, lay the raceways and make
the electrical connections of the 844 T electronic unit to the
selected accessories.
Always separate power cables from control and safety cables
(push-button  receiver, photocells, etc.). To prevent any electronic
noise whatever, use separate sheaths.

Fig. 18

Programming

logics A1/A2/S1/S2/E1/E2/B/C

pre-flashing

Motor braking

fixed

Safety timing

255 sec.

5.1.2. 844 T LAY-OUT

1.5

TABLE 3

 844 T CONTROL UNIT COMPONENTS

F1

Fuse F1 5x20  F5A/250V rapid (transformer)

F2

Fuse F2 5x20  T1,6A/250V delayed (accessories)

SW1

RESET push-button

DS1

Programming microswitches

Led

Input status signalling LEDs

J1

Quick-fit plug for decoding cards/RP receivers

J2

Low voltage terminal block for inputs/accessories

J3

Flashlight output terminal block (230V~  max 60W)

J4

Motor output terminal block

J5

Line power supply input terminal block

LK1

Bridge for warning light free contact

RL6-7

Motor relay

RL8

Braking relay

Summary of Contents for 844 MC-T

Page 1: ...e 89 392 EEC and subsequent amendments 91 368 EEC 93 44 EEC and 93 68 EEC complieswiththeessentialsafetyrequirementsinthefollowingEECDirectives 73 23 EEC and subsequent amendment 93 68 EEC 89 336 EEC...

Page 2: ...a all pole switch with contact opening distance of 3mm or greater Use of a 6A thermal breaker with all pole circuit break is recommended 13 Make sure there is a differential switch with 0 03A thresho...

Page 3: ...il bath Protective treatment cataphoresis Appliance 844 T optional Limit switch inductive sensor with plate Gearmotoroveralldimensions LxHxD mm see fig 2 Technicalspecificationsofelectricmotor RPM 140...

Page 4: ...he plinth excavationarea If the gearmotor is exposed to passing vehicles if possible fit adequate guards to protect against accidental impact Check if an efficient earth plate is present for connectio...

Page 5: ...rator for manual operation as explained in paragraph 7 7 Remove and store the breather screw Fig 13 Fig 11 Fig 12 Fig 9 Fig 8 Fig 10 4 4 INSTALLING THE RACK 4 4 1 STEEL RACK TO BE WELDED Fig 14 1 Fit...

Page 6: ...Fig 16 Fig 17 Notes on the rack As the gate moves make sure that no rack elements lose contact with the pinion Do not repeat do not weld the rack elements either to the spacer or to each other After i...

Page 7: ...MPS DECODER SL SLP DS 844MPS 844MPS Installbyfittingtheaccessorycardssothattheircomponentsside faces the inside of the 844 T electronic appliance Insert and remove the cards after cutting power 5 2 2...

Page 8: ...ing if any 2 Pre flashing begins 5 before every movement 5 2 6 SIGNALLINGLEDs 6 LEDs are fitted on the card indicating status of terminal block inputs LED LIGHTED contact closed LED OFF contact open P...

Page 9: ...ation a microprocessorerror b safety electronic timing tripped operation is interrupted if continuous work time exceeds 255 sec c limit sensors disconnected or both engaged Conditions a and b cause au...

Page 10: ...edeviceasfollows 1 Opentheprotectivedoorandfitthesuppliedkeyinthelock Fig 32 2 Turnthekeyclockwiseandpullthereleaseleverasshownin Fig 33 3 Open or close the gate manually To increase torque turn the s...

Page 11: ...When doing maintenance jobs always check that the anti crushing clutch is correctly set and that safety devices are operatingefficiently 10 1 TOPPING UP WITH OIL Periodically check quantity of oil in...

Page 12: ...ng command by remote control or from another suitable device it activates the motor until the opening position is reached If automatic operating mode was set the gate closes auto matically after the s...