844 T TECHNICAL SPECIFICATIONS
Power supply
400V 3ph+N (+6 -10 %) 50Hz
Motor max load
950 W
Accessories power supply
2 4 V d c
Accessories max load
500 mA
Warning light power supply
24V~ (5W max)
A m b i e n t t e m p e r a t u r e r a n g e
- 20°C + 55°C
Fuses
transformer primary winding
accessories
Quick-fit plugs
- for decoding cards or RP receivers -
Inputs
OPEN/PART OPEN/STOP/CLOSURE SAFETY DEVICES/
LIMIT-SENSORS
warning light
Outputs
flashing light
m o t o r
24Vdc accessories power supply
pause time (5-10-15-30-60-120-180 sec.)
Fig. 19
TF1
RL7
RL6
RL8
F1
F2
SW1
DS1
J1
J2
J3
J4
J5
A B STOP FSW FCC FCA
LK1
F1
SW1
J1
Led
LK1
J2
J5
RL6
RL8
RL7
J3
J4
DS1
F2
4.4.2. STEEL RACK TO BE BOLTED (Fig. 15)
1) Manually place the leaf in closed
position.
2) Rest the first section of the rack
level on the pinion gear and insert
the spacer between the rack and
the gate, locating it in the upper
part of the slot.
3) Mark the drilling point on the gate.
Drill Ø 6.5 mm. and tap with a Ø 8
mm. taps. Tighten the bolt.
4) Move the gate by hand, checking whether the rack rests on
the pinion and repeat operations at point 3.
5) Position another rack element next to the previous one, using
a section of rack as in Fig. 17.
6) Move the gate by hand and execute the securing operations
as done for the first element, carrying on until you have
covered the entire gate.
Fig. 15
Fig. 16
Fig. 17
Notes on the rack
•
As the gate moves, make sure that no rack elements lose
contact with the pinion.
•
Do not, repeat do not, weld the rack elements either to the
spacer or to each other.
•
After installing the rack, to ensure correct meshing with the
pinion gear, we advise you to lower the position of the
gearmotor by approximately 1.5 mm
(Fig.18).
•
Manually check that the gate
reaches the mechanical limit stops
correctly, and that there is no fric-
tion during travel.
•
Do not apply grease or other lubri-
cants between rack and pinion.
5. START-UP
5.1. CONNECTION TO ELECTRONIC CONTROL UNIT
Ü
Before attempting any work on the control unit (connections,
programming, maintenance), always turn off power supply.
Observe points 10, 11, 12, 13 and 14 of the GENERAL SAFETY
OBLIGATIONS.
Observing the instructions in Fig.3, lay the raceways and make
the electrical connections of the 844 T electronic unit to the
selected accessories.
Always separate power cables from control and safety cables
(push-button receiver, photocells, etc.). To prevent any electronic
noise whatever, use separate sheaths.
Fig. 18
Programming
logics A1/A2/S1/S2/E1/E2/B/C
pre-flashing
Motor braking
fixed
Safety timing
255 sec.
5.1.2. 844 T LAY-OUT
1.5
TABLE 3
844 T CONTROL UNIT COMPONENTS
F1
Fuse F1 5x20 F5A/250V rapid (transformer)
F2
Fuse F2 5x20 T1,6A/250V delayed (accessories)
SW1
RESET push-button
DS1
Programming microswitches
Led
Input status signalling LEDs
J1
Quick-fit plug for decoding cards/RP receivers
J2
Low voltage terminal block for inputs/accessories
J3
Flashlight output terminal block (230V~ max 60W)
J4
Motor output terminal block
J5
Line power supply input terminal block
LK1
Bridge for warning light free contact
RL6-7
Motor relay
RL8
Braking relay