ENGLISH

a

844 MC-T operator

b

Photocells

c

Key switch

d

Flashing light

e

Radio receiver

f

844 T elec.unit

Fig. 3

2. DIMENSIONS

Fig. 2

Dimensions in mm.

3. ELECTRICAL EQUIPMENT (standard system)

RSTN+ 400V 5x2,5 mm

2

385

280

191

158

209

4. INSTALLATION OF AUTOMATION

4.1. PRELIMINARY CHECKS

To ensure safety and an efficient automation, make sure the
following requirements are met:

The gate structure must be suitable for automation. In par-
ticular, wheel diameter must be in proportion to the weight
of the gate to be automated, an upper guide must be
supplied, and travel limit mechanical stops must be fitted to
prevent the gate from derailing.

The characteristics of the soil must ensure sufficient stability of
the foundation plinth.

There must be no pipes or electrical cables in the plinth
excavation area.

If the gearmotor is exposed to passing vehicles, if possible, fit
adequate guards to protect against accidental impact.

Check if an efficient earth plate is present for connection to
the gearmotor.

4.2. FOUNDATION PLATE MASONRY

1) Assemble the foundation plate as shown in Fig.4.
2) The foundation plate must be positioned as in Fig. 5 (right-

hand closure) or Fig. 6 (left-hand closure) to ensure the rack
and pinion mesh correctly.

3) Prepare a foundation plinth as in Fig.7 and enclose the

foundation plate in a wall providing one or more sheaths for
routing electric cables. Using a spirit level, check if the plate
is perfectly level.  Allow the cement to set.

4) Lay the electrical cables for connection to the accessories

and power supply as in Fig.3.
To facilitate making connections, allow the cables to pro-
trude by about 45 cm from the hole (Fig.5-6 ref.

Œ

) of the

foundation plate.

Fig. 4

Fig. 5

Fig. 6

225

90

°

49

0

÷

50

49

0

÷

50

155

90

°

63

1

1

1

1

1

1

1

1

1

1

Fig. 7

Summary of Contents for 844 MC-T

Page 1: ...e 89 392 EEC and subsequent amendments 91 368 EEC 93 44 EEC and 93 68 EEC complieswiththeessentialsafetyrequirementsinthefollowingEECDirectives 73 23 EEC and subsequent amendment 93 68 EEC 89 336 EEC...

Page 2: ...a all pole switch with contact opening distance of 3mm or greater Use of a 6A thermal breaker with all pole circuit break is recommended 13 Make sure there is a differential switch with 0 03A thresho...

Page 3: ...il bath Protective treatment cataphoresis Appliance 844 T optional Limit switch inductive sensor with plate Gearmotoroveralldimensions LxHxD mm see fig 2 Technicalspecificationsofelectricmotor RPM 140...

Page 4: ...he plinth excavationarea If the gearmotor is exposed to passing vehicles if possible fit adequate guards to protect against accidental impact Check if an efficient earth plate is present for connectio...

Page 5: ...rator for manual operation as explained in paragraph 7 7 Remove and store the breather screw Fig 13 Fig 11 Fig 12 Fig 9 Fig 8 Fig 10 4 4 INSTALLING THE RACK 4 4 1 STEEL RACK TO BE WELDED Fig 14 1 Fit...

Page 6: ...Fig 16 Fig 17 Notes on the rack As the gate moves make sure that no rack elements lose contact with the pinion Do not repeat do not weld the rack elements either to the spacer or to each other After i...

Page 7: ...MPS DECODER SL SLP DS 844MPS 844MPS Installbyfittingtheaccessorycardssothattheircomponentsside faces the inside of the 844 T electronic appliance Insert and remove the cards after cutting power 5 2 2...

Page 8: ...ing if any 2 Pre flashing begins 5 before every movement 5 2 6 SIGNALLINGLEDs 6 LEDs are fitted on the card indicating status of terminal block inputs LED LIGHTED contact closed LED OFF contact open P...

Page 9: ...ation a microprocessorerror b safety electronic timing tripped operation is interrupted if continuous work time exceeds 255 sec c limit sensors disconnected or both engaged Conditions a and b cause au...

Page 10: ...edeviceasfollows 1 Opentheprotectivedoorandfitthesuppliedkeyinthelock Fig 32 2 Turnthekeyclockwiseandpullthereleaseleverasshownin Fig 33 3 Open or close the gate manually To increase torque turn the s...

Page 11: ...When doing maintenance jobs always check that the anti crushing clutch is correctly set and that safety devices are operatingefficiently 10 1 TOPPING UP WITH OIL Periodically check quantity of oil in...

Page 12: ...ng command by remote control or from another suitable device it activates the motor until the opening position is reached If automatic operating mode was set the gate closes auto matically after the s...