8. RESTORING NORMAL OPERATING MODE
To avoid an involuntary pulse from activating the gate during the
manoeuvre, before re-locking the operator , switch off power to
the system.
1)
Re-close the release lever.
2)
Turn the key anti-clockwise.
3)
Remove the key and close the lock protection door.
4)
Move the gate until the release mechanism meshes.
9. SPECIAL APPLICATIONS
There are no special applications.
10.MAINTENANCE
When doing maintenance jobs, always check that the anti-
crushing clutch is correctly set, and that safety devices are
operating efficiently.
10.1. TOPPING UP WITH OIL
Periodically check quantity of oil inside the operator.
An annual check is sufficient for low to medium use frequency; for
heavier duty, check every 6 months.
To access the tank, temporarily remove the oil filling plug (Fig.1
ref.8).
Oil visual check: oil must nearly touch the copper windings of the
electric motor (Fig. 34).
To top up, pour in oil up to the level indicated above.
Use only FAAC XD 220 oil and no other.
11.REPAIRS
For repairs, contact FAAC’s authorised Repair Centres.