background image

16

ENGLISH

ENGLISH

4.3. MECHANICAL INSTALLATION

1) Assemble the securing corner plates and anti-vibration spac-

ers to the operator as shown in Fig. 8.

2) Open the operator cover using the supplied triangular cavity

key as in Fig.9.
The cover stays in open position by means of an appropriate
locking system.

3) Place the operator on the plate using the supplied washers

and nuts as in Fig.10.
When doing this, route the cables through the raceway in the
operator’s lower half-body.
To access Interface card 844,  route the cables through the
appropriate holes (Fig.1. ref.11), using the supplied cable
grippers.

4) Adjust height of the feet and distance from gate, consulting

Fig.11.

5) Secure the gearmotor to the foundation plate, tightening the

nuts as shown in Fig.12.

6) Prepare the operator for manual operation as explained in

paragraph 7.

7) Remove and store the breather screw (Fig.13).

Fig. 11

Fig. 12

Fig. 9

Fig. 8

Fig. 10

4.4. INSTALLING THE RACK

4.4.1. STEEL RACK TO BE WELDED (Fig.14)

1) Fit the three threaded pawls on the

rack element, locating them in the
upper part of the slot.  In this way,
play on the slot will accommodate
any adjustments that may be neces-
sary later on.

2) Manually place the leaf in closed

position.

3) Rest the first section of the rack level

on the pinion gear, and weld the threaded pawl on the gate
as shown in Fig.16.

4) Move the gate by hand, checking whether the rack rests on

the pinion gear, and weld the second and third pawl.

5) Position another rack element next to the previous one, using

a section of rack as in Fig.17, to synchronize the teeth of the
two elements.

6) Move the gate by hand and weld the three threaded pawls,

carrying on until you have covered the entire gate.

Fig. 14

Fig. 13

5 max

43

112 (

Z

16)

120 (

Z

20)

64

49

15 ÷

 32

Summary of Contents for 844 MC-T

Page 1: ...e 89 392 EEC and subsequent amendments 91 368 EEC 93 44 EEC and 93 68 EEC complieswiththeessentialsafetyrequirementsinthefollowingEECDirectives 73 23 EEC and subsequent amendment 93 68 EEC 89 336 EEC...

Page 2: ...a all pole switch with contact opening distance of 3mm or greater Use of a 6A thermal breaker with all pole circuit break is recommended 13 Make sure there is a differential switch with 0 03A thresho...

Page 3: ...il bath Protective treatment cataphoresis Appliance 844 T optional Limit switch inductive sensor with plate Gearmotoroveralldimensions LxHxD mm see fig 2 Technicalspecificationsofelectricmotor RPM 140...

Page 4: ...he plinth excavationarea If the gearmotor is exposed to passing vehicles if possible fit adequate guards to protect against accidental impact Check if an efficient earth plate is present for connectio...

Page 5: ...rator for manual operation as explained in paragraph 7 7 Remove and store the breather screw Fig 13 Fig 11 Fig 12 Fig 9 Fig 8 Fig 10 4 4 INSTALLING THE RACK 4 4 1 STEEL RACK TO BE WELDED Fig 14 1 Fit...

Page 6: ...Fig 16 Fig 17 Notes on the rack As the gate moves make sure that no rack elements lose contact with the pinion Do not repeat do not weld the rack elements either to the spacer or to each other After i...

Page 7: ...MPS DECODER SL SLP DS 844MPS 844MPS Installbyfittingtheaccessorycardssothattheircomponentsside faces the inside of the 844 T electronic appliance Insert and remove the cards after cutting power 5 2 2...

Page 8: ...ing if any 2 Pre flashing begins 5 before every movement 5 2 6 SIGNALLINGLEDs 6 LEDs are fitted on the card indicating status of terminal block inputs LED LIGHTED contact closed LED OFF contact open P...

Page 9: ...ation a microprocessorerror b safety electronic timing tripped operation is interrupted if continuous work time exceeds 255 sec c limit sensors disconnected or both engaged Conditions a and b cause au...

Page 10: ...edeviceasfollows 1 Opentheprotectivedoorandfitthesuppliedkeyinthelock Fig 32 2 Turnthekeyclockwiseandpullthereleaseleverasshownin Fig 33 3 Open or close the gate manually To increase torque turn the s...

Page 11: ...When doing maintenance jobs always check that the anti crushing clutch is correctly set and that safety devices are operatingefficiently 10 1 TOPPING UP WITH OIL Periodically check quantity of oil in...

Page 12: ...ng command by remote control or from another suitable device it activates the motor until the opening position is reached If automatic operating mode was set the gate closes auto matically after the s...