![Extron electronics SMD 101 User Manual Download Page 94](http://html1.mh-extra.com/html/extron-electronics/smd-101/smd-101_user-manual_2456436094.webp)
Configuring the Alarm Message List
From the list, click on the radio button of the desired action in the presence of each type of
alarm.
Alarm types (
) include:
•
App Unresponsive
— This alarm activates when an app fails but is recoverable.
•
Auth Failures
— This alarm activates if excessive failed login attempts are detected.
•
CPU Usage
— This alarm activates when the device CPU exceeds 90% utilization for
75% of a 5 minute window.
•
NTP Sync
— This alarm activates if the SMD attempts to automatically sync with the
configured NTP server and fails the primary and retry attempts.
•
Player Error Fatal
— This alarm activates when the player fails to respond within
1 minute. The unit is restarted automatically if necessary.
•
Source Audio Underflow
— This alarm activates when there is insufficient audio data.
This is occasionally see with live streams. Increasing the buffer setting, increasing the
audio bit rate, or reducing the video bit rate can help to avoid the condition.
•
Temperature Internal
— This alarm activates if the SMD unit temperature exceeds
60°C for 2 minutes.
•
Source Loss
— This alarm activates when the selected input source is unavailable
such as a network stream that is disconnected or a mounted drive removed.
Actions (
) include:
Icon
Action
Description
Notify
This option sends an e-mail to the designated recipient each time
a corresponding alarm is triggered. The alarm is also displayed and
logged.
Display
This option displays a notice of the alarm condition within the
SMD embedded web pages and the front panel display when the
corresponding alarm condition occurs. No e-mail is sent. The event
is logged.
Log
This option lists the corresponding alarm in the events log, accessed
by clicking
Troubleshooting>Logs
. No e-mail is sent.
Disabled
If this option is selected, the device does not create a log or
notification for the corresponding alarm type.
SMD 101 • Web-based User Interface