![Extron electronics SMD 101 User Manual Download Page 128](http://html1.mh-extra.com/html/extron-electronics/smd-101/smd-101_user-manual_2456436128.webp)
Command and Response Table for Basic SIS Commands (continued)
NOTES:
X#
= Greenwich Mean Time offset
GMT offset value (– 12:
00
to 14:
00
) representing hours and minutes
(HH:MM) local time is offset from GMT time
X%
= On/Off status
0
=off/disable
1=on/enable
X1@
= Unit name
Alpha-numeric up to 24 characters. No special characters except hyphen (-)
No upper/lower case distinction, no blanks or spaces, first character must be
alpha, last character cannot be hyphen.
X1#
= Local date/time
Set:
MM/DD/YY-HH:MM:SS
Read:
day of week, date, month, year HH:MM:SS
(for instance; Fri, 21 Jun
2002
10:54:00
)
X1$
= IP Address
default 192.168.254.254
X1*
= Hardware MAC address
00-05-A6-xx-xx-xx
X1(
= Subnet mask
Default
255.255.0.0
X2@
= Verbose/Response mode
0
=clear (default for IP), 1=verbose (default for serial and USB),
2=tagged responses, 3=v tagged responses
X3$
= Daylight Saving time
0
=off/ignore;
1= USA (begins first Sunday in April/ends last Sunday in October);
2= Europe (begins last Sunday in March/ends last Sunday in October);
3= Brazil (begins third Sunday in October/ends third Saturday in March).
X4(
= Alpha-numeric unit name
combination of unit name and last three pairs of MAC address
NOTES:
X51@
= Temperature
Internal temperature in Celsius
X60@
= IR Input
0
= disabled
1
= front (default)
2
= rear panel
X60#
= PSAV state
0
= inactive (default)
1
= active
X60$
= Standby timer
0
to
500
minutes
0
= off
235
= default
Command
ASCII Command
(host to unit)
Response
(unit to host)
Additional
Description
System Commands
Configuration
Save box
configuration
E
1*{config
type}XF
}
Cfg1*{config
type}
]
Restore box
configuration
E
0*{config
type}XF
}
Cfg0*{config
type}
]
Load a configuration file.
IR
Control
Set IR input
E X60@
IREN
}
Iren
X60@
]
View IR input
E
IREN
}
X60@]
KEY:
X60@
X60@
= IR Input
0
= disabled
Power
Save
and
Standby
Set the power save
mode
E X60#
PSAV
}
Psav
X60#
]
View the power save
mode
E
PSAV
}
X60#]
Set standby timer
E X60$
PTIM
}
Ptim
X60$
]
View standby timer
E
PTIM
}
X60$
]
Internal temperature
E
20STAT
}
X51@]
Temperature in Celsius.
KEY:
X51@
X51@
= Temperature
Internal temperature in degrees Celsius.
X58%
X58%
= System software upgrade operation (UPGS) status (see the
on page 116)
X60#
X60#
= PSAV state
0
= inactive (default)
1
= active
X60$
X60$
= Standby timer
0
to
500
minutes
0
= off (default)
Resets
Reboot system
E
1BOOT
}
Boot1
]
Complete system reboot.
Restart the network
E
2BOOT
}
Boot2
]
Reset flash
E
ZFFF
}
Zpf
]
Reset flash memory
(erase user-supplied files).
System reset (factory
defaults)
E
ZXXX
}
Zpx
]
Reset all device
settings and delete
files
E
ZY
}
Zpy
]
Reset to default except IP
address, delete all user files.
NOTE:
This reset excludes IP settings such as IP address, subnet mask, gateway IP address, unit name, DHCP setting and
port mapping (telnet/Web/direct access) in order to preserve communication with the device.
This reset is recommended after a firmware update.
Absolute reset
E
ZQQQ
}
Zpq
]
System
Reset
, plus returns the
IP address and subnet mask to
defaults.
121
SMD 101 • Remote Communication and Control
Summary of Contents for SMD 101
Page 2: ......