![Extron electronics SMD 101 User Manual Download Page 93](http://html1.mh-extra.com/html/extron-electronics/smd-101/smd-101_user-manual_2456436093.webp)
Alarms
The
Alarms
page contains settings to configure the SMD 101 to generate e-mail
notifications or display warnings if certain events occur during operation.
To open this page, click the
Advanced
Configuration
tab at the top of the SMD 101
embedded web pages and then click the
Alarms
icon on the global navigation bar. The
Alarms
page opens (see figure 80).
Figure 80.
Alarms Page
Configuring Alarm Notifier Destinations
To configure the Alarms to be sent via e-mail:
1.
Enter an e-mail address into the
"From"
User
ID
field (see figure 80,
1
). This address
is shown as the sender for the alarm notification.
2.
Enter an e-mail address into the
"To"
User
ID
field (
2
). This is the e-mail address to
which the alarm notifications will be sent.
3.
Enter the address for the e-mail server into the
Address
Server
field (
3
).
4.
From the
Use
Encryption
drop-down list (
4
), select whether to use encryption, and
which type to use.
5.
Enter the TCP port number into the
TCP
Port
field (
5
).
6.
If desired, enter
Username
(
6
) and
Password
(
7
) information into those fields.
NOTE:
The
Options
field (
8
) is reserved for future use.
SMD 101 • Web-based User Interface
86
Summary of Contents for SMD 101
Page 2: ......