Installation and
Operation
This section describes the installation and the operation of the IPL T CR48. Topics that are
covered include:
•
•
•
Rear Panel Features and Cabling
•
Installation Overview
To install and set up the IPL T CR48, follow these steps:
1.
Turn all of the equipment off. Make sure that the input devices (such as motion
detectors and alarms), the IPL T CR48, and the output devices (such as projectors or
screen lifts) are all turned off and disconnected from the power source.
2.
Mount the IPL T CR48 unit (see “Mounting the IPL T CR48”).
3.
Attach the cables (see
4.
Connect power cords and turn on the devices in the following order: output devices
(projector lifts, screen lifts, lighting system, and so on), IPL T CR48, serial controller or
computer (PC), then input devices (DSS, cable boxes, and so on).
5.
Configure the IPL T CR48 through Telnet, then access the unit using an Internet
browser.
Mounting the IPL T CR48
Optional rack shelves and an assortment of mounting kits (furniture and projector mount)
are available for use with the IPL T CR48 controller (see
instructions provided with the rack shelf or mounting kit for installation procedures.
The IPL T CR48 includes rubber feet so that it can be set on a table. If you are going
to mount the unit to a rack shelf, furniture, or pole, and these feet were attached to the
controller, remove the feet before mounting.
UL Guidelines for Rack Mounting
The following Underwriters Laboratories (UL) guidelines pertain to the installation of an
IPL T CR48 unit onto a rack.
1.
Elevated operating ambient
—
If installed in a closed or multi-unit rack assembly,
the operating ambient temperature of the rack environment may be greater than
room ambient. Therefore, consider installing the equipment in an environment
compatible with the maximum ambient temperature specified by the manufacturer
(Tma = +32 to +122 °F [0 to +50 °C]).
IPL T CR48 • Installation and Operation
3