User Guide
IPL T CR48
IP Link
®
IP Link Ethernet Control Interface
68-738-05 Rev. D
08 19
Page 1: ...User Guide IPL T CR48 IP Link IP Link Ethernet Control Interface 68 738 05 Rev D 08 19...
Page 2: ...a en el producto avisa al usuario de la presencia de importantes instrucciones de uso y mantenimiento recogidas en la documentaci n proporcionada con el equipo Para obtener informaci n sobre directric...
Page 3: ...PoleVault PowerCage PURE3 Quantum Show Me SoundField SpeedMount SpeedSwitch StudioStation System INTEGRATOR TeamWork TouchLink V Lock VideoLounge VN Matrix VoiceLift WallVault WindoWall XTP XTP System...
Page 4: ...ence must be corrected at the expense of the user NOTE For more information on safety guidelines regulatory compliances EMI EMF compatibility accessibility and related topics see the Extron Safety and...
Page 5: ...examples of computer or device responses used in this guide the character 0 is the number zero and O is the capital letter o Computer responses and directory paths that do not have variables are writ...
Page 6: ......
Page 7: ...d Configuration 11 Connecting the Hardware 11 Ethernet Connection 11 Contact Closure Input and Relay Connections 12 Configuring the Hardware 12 PC Configuration 12 IPL T CR48 Interface Configuration 1...
Page 8: ...IPL T CR48 Contents viii...
Page 9: ...hosts its own web pages stored in blink memory within the device The IPL T CR48 supports Telnet SMTP Simple Mail Transfer Protocol ICMP Internet Control Message Protocol or Ping and DHCP Dynamic Host...
Page 10: ...enabled AV devices NOTE Ethernet driver support requires Global Configurator 3 0 and firmware version 1 15 or higher Easily connected Provides RJ 45 auto sense 10 100 Mbps Ethernet LAN connection Easi...
Page 11: ...PL T CR48 through Telnet then access the unit using an Internet browser Mounting the IPL T CR48 Optional rack shelves and an assortment of mounting kits furniture and projector mount are available for...
Page 12: ...rthing grounding Reliable earthing of rack mounted equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit such as...
Page 13: ...figure 4 Figure 3 Furniture Mounting the IPL T CR48 Projector PMK 100 Mounting Bolt Figure 4 Projector Mounting the IPL T CR48 Rear Panel Features and Cabling All connections including power input an...
Page 14: ...ical Code ANSI NFPA 70 article 75 and the Canadian Electrical Code part 1 section 16 The power supply shall not be permanently fixed to building structure or similar structure L installation doit touj...
Page 15: ...AN activity Link LED A green LED lights to indicate a good LAN connection A cable that is wired as T568A at one end and T568B at the other Tx and Rx pairs reversed is a crossover cable A cable wired t...
Page 16: ...ons to and from the unit A Reset button 2 is also available from the front panel in a small recess next to the Power LED IPL T CR48 R 4 2 3 1 INPUT 100 LINK ACT 4 2 3 1 RELAY 8 6 7 5 1 2 3 4 5 6 7 Fig...
Page 17: ...ecycled If you want to use the factory default firmware you must upload that version again The IPL T CR48 reverts to the factory default firmware Event scripting does not start if the unit is powered...
Page 18: ...9 seconds until the Power LED blinks three times once at 3 seconds again at 6 seconds again at 9 seconds Then release and press Reset momentarily for 1 second within 1 second Mode 5 performs a complet...
Page 19: ...9 Example Application Ethernet Connection This type of connection is used on an ongoing basis to connect the IPL T CR48 to a LAN and to control switching and display devices through the unit 1 Plug o...
Page 20: ...e IPL T CR48 must be configured correctly The PC must be network capable with the proper protocols installed and the hardware configured correctly The IPL T CR48 must be set to recognize and accept co...
Page 21: ...d and is still set for factory defaults go to step 4 If not perform a Mode 4 system reset see Resetting the Controller on page 9 for detailed information on reset modes NOTE The IPL T CR48 unit must b...
Page 22: ...event of a complete system reset the passwords convert to the default which is no password see Setting and changing passwords on page 19 to change a password 1 Plug one end of a CAT 5 crossover Ether...
Page 23: ...r web browser Internet Explorer and type http 192 168 254 254 index html in the Address field of the browser The IPL T CR48 default web page is displayed See IPL T CR48 Interface Configuration on page...
Page 24: ...ither side of the external switch or relay from the IPL T CR48 Relay Ports The relay ports can be used for remote switching of low level signals The relays can be activated via software in three ways...
Page 25: ...ry configured passwords for all accounts on this device have been set to the device serial number In the event of a complete system reset the passwords convert to the default which is no password see...
Page 26: ...es or switchers To configure system or port settings 1 Select the Configuration tab and the System Settings page see figure 14 is displayed Figure 14 System Settings Page 2 Make changes to the IP sett...
Page 27: ...passwords convert to the default which is no password To set or change the passwords 1 Click the Passwords link on the menu on the left side of the window The Passwords page is displayed see figure 1...
Page 28: ...ach e mail address and file name 1 Enter the e mail address of the alert recipient in one of the numeric mailboxes under Email Address 2 Enter the name of the file containing the alert message under F...
Page 29: ...A file with any other extension is not a firmware upgrade for this device and could cause the device to stop functioning Les fichiers firmware valides doivent contenir l extension fichier S19 Un fichi...
Page 30: ...oad 3 Click Upload File to upload the file The file is added to the list of files under the Files column After ten files have been loaded additional file management pages appear in the page navigation...
Page 31: ...ugh a web browser the URL reference is used below to shorten the examples This would in practice be the full URL of the control interface and web page reference including all path information for exam...
Page 32: ...age return and line feed Carriage return no line feed Space hard character Copyright information c COPYRIGHT 2009 EXTRON ELECTRONICS IPL T CR48 Vx xx 60 544 x5 Tue 10 Aug 2010 16 29 10 The copyright m...
Page 33: ...s of characters do not require encoding in a URL Alphanumerics 0 9 a z or A Z Special characters _ _ Reserved characters When used for their reserved purposes these characters do not require encoding...
Page 34: ...d unsafe The following table lists unsafe characters Characters Hex Dec Space 20 32 Quotation marks 22 34 Less than symbol 3C 60 Greater than symboi 3E 62 Pound 23 35 Percent 25 37 Miscellaneous Chara...
Page 35: ...ver desc UL date and time Query updated firmware version 4Q 4Q X1 plus web ver desc UL date and time NOTE An asterisk placed after the version number indicates which version is currently running A que...
Page 36: ...d local date and time format Day of week date month year HH MM SS X3 Daylight saving time 0 off or ignore 1 on use in northern hemisphere USA 2 on Europe 3 on Brazil X4 Default Name combination of mod...
Page 37: ...ress X2 Verbose or tagged response mode status 0 clear default for Telnet connections 1 verbose mode is enabled 2 send tagged responses for queries 3 verbose mode is enabled and tagged responses are s...
Page 38: ...024 or higher Reset web port map24 E80MH W80MH Pmh00080 Disable web port map24 E0MH W0MH Pmh00000 Read web port map24 EMH WMH port Web Browser Specific Read response from last URL cmd EUB WUB response...
Page 39: ...n set to the device serial number In the event of a complete system reset the passwords convert to the default which is no password see Setting and changing passwords on page 19 to change a password E...
Page 40: ...e IPL T CR48 on a network Once connected via Telnet you can send ASCII serial commands see Programmer Guide for the Telnet and Web Browser on page 23 to control devices connected to the IPL T CR48 Acc...
Page 41: ...omputer should be solid green if a network connection is detected If these LEDs are not lit either the cable is faulty or not plugged in or the wrong type of cable is being used see Connecting the Har...
Page 42: ...protocol that enables network administrators to locally and automatically manage the assignment of IP addresses in a network for an organization Driver A GC compatible package It includes the event sc...
Page 43: ...o the Internet a table see ARP on page 34 relates the IP address of the device to its corresponding physical MAC address on the LAN Pass through Allows control systems to work with the IPL T CR48 and...
Page 44: ...n South Africa South Tower 160 Jan Smuts Avenue Rosebank 2196 South Africa This Limited Warranty does not apply if the fault has been caused by misuse improper handling care electrical or mechanical a...