Testing Fibers in Fault Finder Mode
OTDR
71
Acquiring Traces in Fault Finder Mode
5.
Once the analysis is complete, save the trace by pressing
Quick Save
in the button bar.
The application will use a file name based on the autonaming
parameters you defined (see
Naming Fault Finder Files Automatically
on page 72). This file name appears at the top of the graph.
Note:
The application will only display the
Save File
dialog box if you have
activated the feature to always be prompted when you save a file
and
if
you did not disable the storage features. From the
Save File
dialog box, you
can change the location, the file name and the file format.
5a.
If necessary, change the folder to which the file will be saved by
pressing the
Location
button.
5b.
If necessary, specify a file name.
5c.
Press
OK
to confirm.
I
MPORTANT
If you specify the name of an existing trace, the original file will be
overwritten and only the new file will be available.