RME1-TC User’s Manual - Thermocouple Acquisition Module
Exemys
Appendix
C
Appendix
C. Technical specifications
•
• Input type and quantity
•
• Network Port
•
•
• Leds
• Power
• Isolation
•
•
•
Resolution:
:
Protocols:
:
Serial:
Administration:
:
:
:
Dimensions:
Temperature:
Guarantee:
0,1°C
8 Inputs for thermocouples
.
TCP / IP, ICMP, ARP, DHCP, NBNS, HTTP.
- TELNET.
- ModBus TCP.
- SNMP (versión 1).
- CSV / XML.
Ethernet 10 BaseT, RJ45 connector.
RS232 for device’s configuration.
Power Led, link Led, data Led.
10 to 30 Vdc.
Consumption: 200mA maximum.
Powered with 10 Vdc.
90 mA powered with 30 Vdc.
1200 Vrms (1 minute).
100mm x 22,5mm x 112mm (HeightxWithxLength)
Operating temperature: -5 a 65ºC
Storage temperature: -40 a 75ºC
1 year guarantee.
J, K, T, R, N, E
HTTP Server, password protected.
Telnet console, password protected..
RS232 Serial console.
-
www.exemys.com Rev.
1
Page