Setup
90
27891EN-900-02 / Edition 02/2017
10.13.
MOUNTING THE SAFETY DEVICE NIP GAP,
WORKING WIDTHS 85 MM, 170 MM, 200 MM
Allen screwdriver 6 mm
NOTE
Roller destruction due to incorrect input of the working width (E-models)
›
In general, program the working width of the used safety device via the
operating unit. Else the line force values [N/mm] will not correspond.
Danger of roller destruction in force mode.
In principle, all safety devices for the nip gap are mounted in the
same way. There are only differences in mounting the hopper.
Fig. 63: Mounting safety device for nip gap
1. Mount plastic guides matching the working width.
2. Set the safety device (
a
) for the corresponding working width from above
onto the centering mounts (
b
). Make sure that the safety device sits correctly
on the centering mount.
a
b
c
d