Operation
Barrier M
5.
The version information "UV-Control V x.x" appears on the graphics
display. Then "Barrier M" is displayed on the operator menu.
The green LED "POWER" lights up.
Please note
If the UV disinfection unit is controlled from a major control system
via the external release contact, the message „*ext. release ?” ap-
pears on the display of the operating panel. Only after this external
release is activated, the operation of the UV disinfection unit starts
and the first cleaning cycle is triggered.
On the version with automatic cleaning mechanism, triggering of one
cleaning cycle. The green LED „CLEANING“ lights up.
The lamps commence heating immediately once they are turned on
.
The corresponding number of green LEDs "Lamps....active" light up,
depending on the number of lamps on
.
After a heating-up period of approximately 4 minutes the lamps reach
full intensity - and thus full disinfection efficiency. The green LED UV
lights up. The UV measurement is activated.
The signal contact for „pump on” is activated if after 4 minutes hea-
ting-up period the minimum UV intensity (100 %) is reached.
After a warm-up period of another 10 minutes the lamps regulate into
the optimal power range.
The remaining running time of the heating-up („Start-up”) and the
warm-up („no dim”) period is shown on the display in a submenu
of the status menu „Stat.: xxxxx”.
Please note
If the lamps are switched off, they need about 15 minutes to cool down.
Only after that time the lamps may be switched back on again. Frequent
switching on and off reduces the service life of the lamps considerably!
Please note
If the lamps are switched off via the external voltage-free release con-
tact, the fans in the control cabinet run on for 10 minutes.
Please note
Stand-by UV disinfection units have to be tested at regular intervals.
We suggest once a month.The lamps must be on for a minimum of
1 hour. A short running time may have a negative impact on the ser-
vice life of the lamps.
Summary of Contents for WALLACE & TIERNAN Barrier M 1200
Page 1: ...WALLACE TIERNAN UV DISINFECTION UNIT BARRIER M OPERATING MANUAL...
Page 2: ...2 WT 090 370 000 DE IM 0715 Barrier M Please note Original manual...
Page 96: ...96 WT 090 370 000 DE IM 0715 Spare parts maintenance schedule Barrier M 6...
Page 100: ...100 WT 090 370 000 DE IM 0715 Table of UV alarm levels Barrier M 7...
Page 102: ...102 WT 090 370 000 DE IM 0715 Certificates declarations and statements Barrier M 8...
Page 103: ...Barrier M Certificates declarations and statements 8 103 8 2 QPS certificate...
Page 104: ...104 WT 090 370 000 DE IM 0715 Certificates declarations and statements Barrier M 8...
Page 105: ...Barrier M Certificates declarations and statements 8 105 8 3 NSF certficate...
Page 106: ...106 WT 090 370 000 DE IM 0715 Certificates declarations and statements Barrier M 8...
Page 109: ...Barrier M 109...