82
WT.090.370.000.DE.IM.0715
Operation
Barrier M
5.
Please note
On versions with several lamps:
Numbers are punched into the lamp flange next to the openings for
the lamps. The wires of the connection cable are also numbered.
Ensure correct assignment during connection.
1
Switch the UV disinfection unit off using the emergency OFF
main switch and make sure the unit cannot be switched on
again.
2
Remove the black end caps on both sides by unscrewing the
securing screws. On the version with a manual cleaning
mechanism the end cap is secured on one side by the clea-
ning mechanism. Proceed as follows:
•
Pull out the handle
•
Unscrew the handle and locking screw
•
Unscrew the securing nut
•
Remove the end cap
3
Ensure unit is not connected to mains power and free of vol-
tage.
4
Release the connection wires of the lamp from the terminals
on both sides. If necessary, remove the motor.
5
Unscrew the terminal mounting plate on one side (on units
with an automatic cleaning mechanism, the side without the
motor should be used preferably as the service side).
6
Remove the spring.
7
Carefully remove the used lamp from the quartz sleeve.
Ensure that the lamps are always disposed of correctly.
8
Put on the supplied cotton gloves. Never touch the lamps with
your bare hands!
9
Carefully remove the lamp from the packaging. New lamps are
supplied in a box together with a cleaning cloth (part number
W3T166566) and instructions.
10
Clean the glass with the supplied cleaning cloth or with alco-
hol. Never hold the lamp at one end only. Hold the lamp at
both outer ends.
Summary of Contents for WALLACE & TIERNAN Barrier M 1200
Page 1: ...WALLACE TIERNAN UV DISINFECTION UNIT BARRIER M OPERATING MANUAL...
Page 2: ...2 WT 090 370 000 DE IM 0715 Barrier M Please note Original manual...
Page 96: ...96 WT 090 370 000 DE IM 0715 Spare parts maintenance schedule Barrier M 6...
Page 100: ...100 WT 090 370 000 DE IM 0715 Table of UV alarm levels Barrier M 7...
Page 102: ...102 WT 090 370 000 DE IM 0715 Certificates declarations and statements Barrier M 8...
Page 103: ...Barrier M Certificates declarations and statements 8 103 8 2 QPS certificate...
Page 104: ...104 WT 090 370 000 DE IM 0715 Certificates declarations and statements Barrier M 8...
Page 105: ...Barrier M Certificates declarations and statements 8 105 8 3 NSF certficate...
Page 106: ...106 WT 090 370 000 DE IM 0715 Certificates declarations and statements Barrier M 8...
Page 109: ...Barrier M 109...