Barrier M
Operation
5.
81
5.14
Replacing the UV lamps
Defective lamps should only be replaced with brand new lamps.
The lamps are always supplied in the original packaging and
should not be unpacked until they are ready for mounting.
Warning!
Risk of burns!
Remember that the lamps are hot when they have been in use. Af-
ter use, leave them to cool down for at least 15 minutes.
Warning!
Risk of injury!
The UV lamps contain a small amount of toxic mercury that must
be bound immediately in the event of lamp breakage using either
a mercury collector or a powerful pipette (see 2.5 and 5.15 Lamp
breakage).
Attention!
Risk of damaging the lamp!
When working with the lamps, always wear clean cotton gloves.
Only touch the lamps at both ends if possible.
Please note
On versions with several lamps:
At the end of their service life lamps that have aged are only to be
replaced in sets.
Please note
On versions with several lamps:
If lamp 1 which is immediately in front of the UV sensor is defec-
tive, replace this with the next lamp in the row which has already
been in use. Then mount the new lamp into the empty fitting. This
ensures that UV measurement is affected as little as possible by
irregularly illuminated lamps.
Summary of Contents for WALLACE & TIERNAN Barrier M 1200
Page 1: ...WALLACE TIERNAN UV DISINFECTION UNIT BARRIER M OPERATING MANUAL...
Page 2: ...2 WT 090 370 000 DE IM 0715 Barrier M Please note Original manual...
Page 96: ...96 WT 090 370 000 DE IM 0715 Spare parts maintenance schedule Barrier M 6...
Page 100: ...100 WT 090 370 000 DE IM 0715 Table of UV alarm levels Barrier M 7...
Page 102: ...102 WT 090 370 000 DE IM 0715 Certificates declarations and statements Barrier M 8...
Page 103: ...Barrier M Certificates declarations and statements 8 103 8 2 QPS certificate...
Page 104: ...104 WT 090 370 000 DE IM 0715 Certificates declarations and statements Barrier M 8...
Page 105: ...Barrier M Certificates declarations and statements 8 105 8 3 NSF certficate...
Page 106: ...106 WT 090 370 000 DE IM 0715 Certificates declarations and statements Barrier M 8...
Page 109: ...Barrier M 109...