Model 5010 Time Code Master Manual
Page 5-16
Revision
3.1.1
SERIAL REMOTE CONTROL PROTOCOL
8A Preset Generator User Bit Data
4 bytes
Presets the generator user bits. This
command has no effect when the generator
user bits are being transferred from either
the Reader Time or User Bits. Expects four
bytes of user bit data in DATA Format as
shown below.
UB grp 2
UB grp 1
UB grp 4
UB grp 3
UB grp 6
UB grp 5
UB grp 8
UB grp 7
A9 Sense
Generator
1 byte
Defines a block of data which will be sent in response to a Sense Generator command.
GU --- --- --- GT --- --- ---
Each bit represents a block of data that is requested. Time and user bit data blocks are defined in
section 4.5 of this manual. The bits are polled and blocks are assembled in the following order:
GT GU
AB Sense Generator Date Format
Returns 1 byte as defined below.
8B Select Generator Date Format
1 byte
Sets the Date Format for the Generator.
ASSIGNMENT
DESCRIPTION
00
YYMMDD
01
Modified Julian Date
02
Other (Leitch Master Clock)
AC
Sense Generator Zone Adjust
Returns 1 byte as defined below.
8C Select Generator Zone Adjust
1 byte
Sets the Time Zone Adjust parameter for
the Generator.
ASSIGNMENT DESCRIPTION
00
Display UTC Reader time.
01
Display Local Reader time.