Model 5010 Time Code Master Manual
Page 5-6
Revision
3.1.1
SERIAL REMOTE CONTROL PROTOCOL
Command from Controlling Device
Return to Controlling Device
CMD
DATA
BYTES
DESCRIPTION
CMD
ECHO
BYTES
DATA
BYTES
NAME
80
1
Select Generator Mode
ACK
81
2
Preset VITC Generator Lines
ACK
82
1
Select Generator Drop Frame
ACK
83
1
Select Generator Color Frame
ACK
84
1
Select LTC Generator Parity
ACK
85
1
Select Vitc Generator On/Off
ACK
86
1
Select Generator Run/Hold
ACK
87
1
Select Gen Jam Sync Mode
ACK
88
1
Select Gen No Code Jam
ACK
89
4
Preset Generator Time
ACK
8A 4
Preset
Generator User Bits
ACK
8B
1
Select Generator Date Format
ACK
8C
1
Select Generator Time Zone Adjust
ACK
A0
Sense Generator Mode
1
1
Generator Mode
A1
Sense VITC Generator Lines
1
2
VITC Generator Lines
A2
Sense Generator Drop Frame
1
1
Generator Drop Frame
A3
Sense Generator Colour Frame
1
1
Generator Colour Frame
A4
Sense LTC Generator Parity
1
1
LTC Generator Parity
A5
Sense VITC Generator On/Off
1
1
VITC Generator On/Off
A6
Sense Generator Run/Hold
1
1
Generator Run/Hold
A7
Sense Gen Jam Sync Mode
1
1
Generator Jan Sync Mode
A8
Sense Generator No Code Jam
1
1
Generator No Code Jam
A9
1
Sense Generator
2
x
Generator Data
AB
Sense Generator Date Format
1
1
Gen Date Format
AC
Sense Generator Time Zone Adj.
1
1
Gen Time Zone Adj.
Table 5-6: Generator Commands and their Valid Responses
Command from Controlling Device
Return to Controlling Device
CMD DATA
BYTES
DESCRIPTION CMD
ECHO
BYTES
DATA
BYTES
NAME
C0
5
Preset Auxiliary Register
ACK
E0
1
Sense Auxiliary Register 2
4
Auxiliary
Register