Model 5010 Time Code Master Manual
Page 5-8
Revision
3.1.1
SERIAL REMOTE CONTROL PROTOCOL
5.6.
COMMAND AND RESPONSE DESCRIPTIONS
5.6.1. System
Commands
01
Enter Select Mode
02
Enter Broadcast Mode
03
Enter Programming Mode
04 Reserved
10
Sense Error Number
Returns 2 bytes
11
Sense PROM Version
1 byte
00 = Boot PROM version
01 = Flash PROM version
Returns the control byte from the c10 (hex) bytes PROM name + 10 (hex) bytes PROM
version
0B Select Video Standard
1 byte
Presets the Video Standard that is being
used
00 = Auto
01 = NTSC
02 = PAL
1B Sense Video Standard
Returns 2 bytes as described in the Select
Video Standard Command.
1C
Sense GPO Assignment
GPO No
Returns 1 byte of GPO assignment as
defined
below.
0C Select GPO Assignment
GPO No +1 byte Presets the Function of the General Purpose
Outputs. The first byte indicates which
general purpose output is being assigned:
GPO No
1
GPO1
2
GPO2
The second byte specifies the function.