Model 5010 Time Code Master Manual
OPERATING INSTRUCTIONS
Revision 3.1.1
Page 4-13
4.5.
PROGRAMMING THE GENERATOR SETUP FUNCTIONS
Figure 4-7: GENERATOR Drop Down Menu
The GENERATOR drop down menu is used to program various generator modes such as selecting
Drop Frame, Colour Frame, Jam Sync Modes, VITC Generator Line numbers, whether user bits
contain static numbers or time information, etc. Figure 4-7 shows the items on the GENERATOR drop
down menu. The following descriptions appear in the order they appear on the menu.
GENERATOR
GEN MODE
TIME
USERBITS
TIME
DATA
TIME
RDR TIME
TIME
RDR UB
TIME
DATE
CONVERT 25
⇔
30
GEN VITC LINES
LINE 1 LINE 2
10
20
DROP FRAME
NON DROP FRAME
DROP FRAME
NOT APPLICABLE IN JAM
NOT APPLICABLE IN PAL
COLOUR FRAME
2 FIELD
4 FIELD
8 FIELD
LTC PARITY
OFF
ON
NO CODE JAM
RUN
HOLD
MUTE
DATE FORMAT
YY MM DD
MODIFIED JULIAN
OTHER
TIME ZONE ADJUST
UTC
LOCAL TIME