37
ENGLISH
The movement of the blast chiller shall be performed using a fork lift or pallet trucks equipped
with suitable forks (length of at least 2/3 of the unit).
The dimensions and masses of the refrigerated cabinets packed are shown in Table 1.
The limits of stackability and the centre of gravity are indicated on the label of the package.
13.1 Positioning operations
Since the incorrect positioning of the blast chiller can cause damage to the same, jeopardizing its proper
functioning and result in risk to the personnel, the installer must adhere to the following general rules:
- keeping a minimum distance of 3 cm from any wall and 50 cm from ceiling
- the environment must be sufficiently ventilated
- position the blast chiller away from heat sources
- do not install outdoors without suitable protective covering
- avoid exposure to direct sunlight
- remove the polyethylene, cardboard or wood packaging
Polyethylene is dangerous for children
- remove any accessories with external connections
Removing the wooden base (Fig.4): lift the blast chiller and remove the base.
Fig.4
use protective gloves when handling the wooden packaging and the wooden base.
The presence of splinters may cause damage to your hands
- remove the PVC film applied as a protection to the outer surfaces of the blast chiller
- position the blast chiller using a level with possible adjustment models PROFESSIONAL TRAY of
the feet of the metal base (Fig. 5)
Fig.5