HIGH EVAPORATOR
TEMP.
High evaporator tempera-
ture
Evaporator temperature
has exceeded the maxi-
mum set value
- Check internal fans
- Service
CYCLE DURATION
Blast chilling or shock free-
zing were not ended within
their maximum duration
Product has not reached
the minimum set tempera-
ture within the set times for
automatic blast-chilling or
shock-freezing cycle
- Check internal fans
- Check product size
- Service
BASE COMMUNICATION
Communication error
between user interface and
control module
Communication problems
between interface and con-
trol module
- Check interface - control
module connection
- Service
POWER FAILURE
Power failure alarm
Power interruption alarm
Check electrical connection
SANIFICATION CORE
PROBE INSERTION
Sanification alarm
Sanification cycle has been
stopped for core probe
insertion alarm
- Check the correct inser-
tion of probe into product
SANIFICATION DURA-
TION
Sanification cycle alarm
Sanification has not ended
because set temperature
was not reached
- Check core probe inser-
tion
- Check product quantity
OVERHEATED CONDEN-
SER
High condenser temperatu-
re alarm
Condenser temperature
has exceeded maximum
value for good operation
- Clean the condenser
- Check condenser fan
BLOCKED COMPRESSOR Condenser temperature
safety alarm
Condenser temperature
has exceeded the safety
value
- Clean the condenser
- Check condenser fan
CORE PROBE INSER-
TION
Alarm for not inserted
probe
Probe has not been inser-
ted into product and the se-
lected program requires it
- Check the correct inser-
tion of probe
EXPANSION COMMUNI-
CATION
Communication error
between user interface and
expansion module
Communication problems
between interface and
expansion module
Service