33
ENGLISH
9.10 HACCP Alarms
If there have been any alarms to access the
alarm area push the
HACCP
key on the
HOME
screen to access the HACCP alarm area.
The alarms of the HACCP list are:
- Blast chilling/shock freezing cycle duration
- Power failure
- Open door
- High temperature alarm
- Low temperature alarm
5°C
Slow Cooking
Proofing
Blast Chiller
Thawing
HACCP
Conservation
11:38
HACCP
11:38
Slow Cooking
Proofing
Thawing
Conservation
Cookbook
SPECIAL CYCLES
11:38
BLAST CHILLER
PRE-COOLING
COOKBOOK
HACCP
PRE-COOLING
5°C
START
-10°C
-6°C
STOP
X X
PRE-COOLING
PRE-COOLING
PRESS TO START
11:38
11:38
11:38
SCROLL TO UNLOCK
13:35
HACCP
15:50 10/04/2019
15:50 10/04/2019
Start
Stop
01 / 20
CYCLE DURATION
25 °C
High temperature
11:38
Alarm list
Needle Probe
9.11 HACCP alarm archive visualization
With the “HACCP” function it is possible to store up to 20 events, after which the more recent
event overwrites the oldest. Access HACCP alarm area and push the
PRESS TO START
11:38
11:38
11:38
SCROLL TO UNLOCK
13:35
HACCP
15:50 10/04/2019
15:50 10/04/2019
Start
Stop
01 / 20
CYCLE DURATION
25 °C
High temperature
11:38
Alarm list
Needle Probe
keys to
visualize all alarms.
9.12 Other alarms
By pressing the “danger”
5°C
Slow Cooking
Proofing
Blast Chiller
Thawing
HACCP
Conservation
11:38
HACCP
11:38
Slow Cooking
Proofing
Thawing
Conservation
Cookbook
SPECIAL CYCLES
11:38
BLAST CHILLER
PRE-COOLING
COOKBOOK
HACCP
PRE-COOLING
5°C
START
-10°C
-6°C
STOP
X X
PRE-COOLING
PRE-COOLING
key, any active alarms “ON” are displayed
ALARM
DESCRIPTION
CAUSE
SOLUTION
RTC
Internal clock alarm
Lack of calibration
Set the clock
CHAMBER PROBE
Chamber probe failure
alarm
Faulty chamber probe
Replace probe
EVAPORATOR PROBE
Evaporator probe failure
alarm
Faulty evaporator probe
Replace probe
CONDENSER PROBE
Condenser probe failure
alarm
Faulty condenser probe
Replace probe
CORE PROBE
Core probe failure alarm
Faulty core probe
Replace probe
HIGH PRESSURE
Refrigerating unit gas
pressure has exceeded the
maximum safety limit
- Dust-clogged condenser
- Idle condenser fan
- Clean the condenser
- Check the condenser fan
LOW PRESSURE
Refrigerating unit gas
pressure is lower than the
minimum operation limit
- Closed liquid electrovalve
- Faulty thermostatic valve
- Gas leak
-Service
-Service
-Service
OPEN DOOR
Open door alarm
The door has remained
open beyond the maximum
set time
- Close the door
- Check door microswitch
HIGH CHAMBER TEMPE-
RATURE
High chamber temperature Chamber temperature has
exceeded the maximum set
value
- Check refrigerating unit
- Service
LOW CHAMBER TEMPE-
RATURE
Low chamber temperature
Evaporator temperature is
lower than the minimum set
value
- Check refrigerating unit
- Service