7.3.9.5 I/O Control
The I/O Control setup menu is used to define the settings for controlling the mobile DVR through
RS-232 communication protocol. Please note that to perform the I/O function, the optional
accessory, External I/O Box, is required.
RS-232
Type:
Select Control or Text Insert.
Baud Rate:
This field is to set the speed at which is used to transmit instruction or information
through the RS-232 port on the mobile DVR. There are eight different speeds: 1200 BPS, 2400
BPS, 4800 BPS, 9600 BPS, 19200 BPS, 38400 BPS, 57600 BPS and 115200 BPS.
Data Bit:
This field is the data bit at which you will be transferring. There are two settings for
this option: 8 or 7.
Stop Bit:
This field is to set the stop bit for the RS-232 connection. There are two different stop
bits, 1 or 2.
Parity:
This field is to select the parity level at which you will be connected. You can choose
between None, Odd, or Even parity levels.
Note:
For details on the RS-232 related settings, please consult the Technical Support
Department of EverFocus.
GPS
Baud Rate:
This field is to set the speed at which is used to transmit instruction or information.
There are eight different speeds: 1200 BPS, 2400 BPS, 4800 BPS, 9600 BPS, 19200 BPS, 38400 BPS,
57600 BPS and 115200 BPS.
Data Bit:
This field is the data bit at which you will be transferring. There are two settings for this
option: 8 or 7.
Stop Bit:
This field is to set the stop bit for the RS232 connection. There are two different stop bits,
1 or 2.