EMV400S FHD / EMV400SSD Mobile DVR
155
7.3.4.2 Video Loss
You can enable Video Loss Event function and configure video loss notifications in this menu.
Camera:
Select a camera to be configured.
Enable:
Check the box to enable the Video Loss event settings for the selected camera.
Log:
Check the box to record video loss events to log data.
Pre-alarm Record:
Check the box to start copying the recordings to the storage from 5 seconds
before the alarm event occurs. The pre-alarm recording rate will follow the Normal Speed
configured in the earlier section (see
7.3.2.1 Basic Setting
). Note that the Pre-Alarm recording
time may be reduced from 5 seconds when the system loading is too heavy, e.g., when all
channels are triggered for pre-alarm recording simultaneously.
Buzzer:
Check the box to enable the buzzer when a video loss event is triggered.
Email Notify:
Check the box to send email notification when a video loss event is detected.
Email operation requires valid email entered in the Email setup menu (see
7.3.7.4 Email
).
Network Alarm:
Check the box to send out a network alarm to a client PC when video loss
event occurs. This feature works with EverFocus’ CMS software. You will need to configure the
Alarm Server for the mobile DVR to send network alarms to the client PC (see
7.3.7.7 Alarm
Server
).
Send to Xfleet:
Check the box to send the event data to the Xfleet system. Note that for the
Xfleet system to receive event data from the mobile DVR in order to perform the event actions
on Xfleet system, this function must be enabled.
Alarm Output:
Select an alarm output number. When an alarm is triggered, the signal will be
transmitted through the alarm output relay.
Output Type:
Select an output type when an alarm is triggered.
Timeout: Select this option and then set up the Timeout Duration in the field below, the
alarm output will last for the setup duration time (10 ~ 150 seconds).