NAV Series TCP/IP Standalone Network Access Controller
31
For
setting
“minutes,”
input
three
digits
in
the
range
of
0
‐
999
and
for
setting
“seconds,”
input
two
digits
in
the
range
of
0
‐
59.
Press
“#”
to
confirm
and
the
setting
will
take
effect.
Press
“*”
to
exit
and
the
setting
will
not
take
effect.
4.6.3 Door Access Mode
Scroll
to
“Door
Access
Mode”
menu
item
and
press
“#”
to
enter
the
submenu.
Scroll
to
select
the
door
open
mode
and
press
the
numerical
key
“5”
to
select.
The
selected
item
is
marked
with
a
“*”.
Then,
press“*”
or“#”
to
exit
the
current
interface.
4.7 Alarm
Setting
The
EFC301
controller
provides
one
alarm
input
circuit
and
one
alarm
output
circuit.
Users
can
carry
out
detailed
configurations
through
the
user
interface.
Details
will
be
introduced
below.
4.7.1 Composition of Alarm
The
alarm
input
of
the
EFC301
controller
can
be
connected
with
external
alarm
equipment
such
as
a
PIR
sensor,
glass
breakage
sensor,
etc
and
the
alarm
output
can
drive
a
4A
alarm
relay.
4.7.2 Basic Configuration of the Alarm
The
EFC301
controller
will
record
all
events
such
as
entry
permit,
entry
prohibition,
etc.
Some
dangerous
events
are
required
to
trigger
alarm
output,
such
as
fire
alarm
input,
protection
area
alarm
input,
etc.
Some
events
do
not
need
alarm
output,
such
as
card
swiping
operations
at
invalid
times.
Whether
the
alarm
is
required
to
be
triggered
will
be
set
according
to
the
user’s
requirement.
EFC301
collects
all
the
event
records
that
may
trigger
alarm
output
and
makes
effective
or
ineffective
alarm
choices
of
these
events.
All
major
events
can
be
set
to
trigger
alarms,
such
as
alarm
input
signals,
unknown
cards,
expired
cards,
invalid
cards,
invalid
door
regions,
invalid
times,
anti
‐
passback
failure,
wrong
password,
wrong
system
password,
wrong
protection
setup/withdrawal
password,
forced
door
open,
Door
Over
Time
and
remote
alarm.
The
detailed
setup
method
will
be
introduced
below.
4.7.3 Enter Alarm Setting Menu
In
the
“System
Setting”
main
menu,
scroll
to
“Alarm
Setting”
menu
item
and
press
“#”
to
enter
the
submenu.
The
submenu
of
the
“Alarm
Setting”
has
“AlarmIN
Setting”
and
“Alarm
Action
Setting”
submenu
items
for
setting
physical
alarm
input
and
alarm
output
time
of
alarm
events,
respectively.
Normal Close
Normal Open
Follow schedule
*Card Only
Card + PIN
Card or PIN