NAV Series TCP/IP Standalone Network Access Controller
30
4.6 Door
Setting
EFC301
controls
a
single
door.
The
user
can
set
the
door
open
time,
Door
Over
Time
and
door
open
mode.
In
the
“System
Setting”
main
menu,
scroll
to
the
“Door
Setting”
menu
item
and
press
“#”
to
enter
the
“Door
Setting”
submenu.
Scroll
to
select
different
menu
items.
4.6.1 Set Open Time
The
door
open
time
is
the
door
open
time
after
the
valid
card
is
swiped
or
the
door
open
button
is
pressed
and
the
default
value
is
3
seconds.
The
maximum
time
set
on
the
controller
is
999
min
59s.
if
the
door
open
button
is
pressed,
the
door
will
open.
The
door
open
time
is
started
after
the
door
open
button
is
released.
Scroll
to
the
“Set
Open
Time
”
menu
item
and
press
“#”
to
enter
its
interface.
For
setting
the
minutes,
input
three
digits
in
the
range
of
0
‐
999,
and
for
setting
seconds,
input
two
digits
in
the
range
of
0
‐
59.
Press
“#”
to
confirm
and
the
setting
will
take
effect.
Press
“*”
to
exit
and
the
setting
will
not
take
effect.
4.6.2 Set Over Time
The
door
status
switch
is
used
to
detect
the
open/closed
status
of
the
door.
In
general
cases,
the
door
is
closed.
In
case
of
door
opening,
the
door
should
be
closed
after
being
opened
for
a
period
of
time,
during
which
the
controller
may
not
receive
the
signal
from
the
door
status
switch.
At
the
end
of
the
door
open
time,
if
a
door
which
should
be
closed
is
not
closed,
timing
will
start
and
the
recorded
time
is
the
Door
Over
Time.
When
the
time
has
exceeded,
the
controller
will
generate
an
alarm.
The
default
Door
Over
Time
is
10s.The
maximum
Door
Over
Time
set
on
the
controller
is
999
min
59s.
Scroll
to
“Set
Over
Time”
menu
item
and
press
“#”
to
enter
its
interface.
Door Over Time
000 Min 10 Sec
Cancel
OK
Door Open Time
000 Min 03 Sec
Cancel
OK
Set Open Time
Set Over Time
Door Access Mode