Feature
Description
Electrical safety
Integrated RCBO 40 A for 30 mA AC leakage detection
per outlet.
CCID 6 mA DC leakage detection per outlet.
RCBO type
2 x Schrack AK667840, Type A, characteristic C, 6 kA,
3+N, 40 A
Surge protection
4 kV.
Black-out protection
Return to previous status after power loss.
Operating temperature range
-25 °C to +45 °C.
Operating humidity (non-regulating)
85 % at 50 °C (non-condensing).
Maximum installation altitude
2000 m above sea level.
Enclosure degree of protection
IP55 / IK10 / IEC 60529.
Certification
IEC 61851-1 (2017), IEC 61851- 21-2 (2018), IEC 61000-3-2
(2014), IEC 61000-3-3 (2013), EN 301 489-1 V2.2.0, EN
301 489-3 V2.1.1, EN 301 489-17 V3.2.0, EN 301 489-52
V1.1.0, EN 301 908- 1 V11.1.1, EN 301 511 V12.5.1, EN
300 330 V2.1.1, EN 300 328 V2.1.1, EN 301 893 V2.1.1,
EN 300 220-1 V3.1.1, EN 300 220- 2 V3.1.1, CE
conformity, RoHS, REACH.
Connectivity
Authorization
RFID and QR code.
Communication standard
Dual band Wi-Fi 2.4/5 GHz, Bluetooth 4.0 for
configuration with the EVBox Connect app, GPS.
Communication protocol to backend
OCPP 1.5 S / 1.6 S / 1.6 J.
Smart Charging using the MAX
protocol
RS485.
Charging station configuration
Using EVBox Connect app.
Physical properties
Plastic materials
ISO 3795 passed, DIN 53438 F1/K1.
EN
3. Product features
12
Summary of Contents for Iqon
Page 1: ...Installation and commissioning manual Part A EVBox Iqon ...
Page 2: ......
Page 3: ...EVBox Iqon Installation and commissioning manual Part A ...
Page 4: ......
Page 18: ...3 4 Dimensions EN 3 Product features 14 ...
Page 23: ...Back to back installation Example dual bay location 4 Installation instructions EN 19 ...
Page 52: ...EN ...
Page 53: ......